Blog

Line surge arresters improving reliability of network in the United States | Hitachi Energy

Choose your region and language

What are you looking for? Metal Enclosures For Electronics

Line surge arresters improving reliability of network in the United States | Hitachi Energy

The power of digital made real

EconiQ Consulting supports customers addressing their unique environmental performance needs

Meet IdentiQ™ digital twin for sustainable, flexible and secure power grids

Service is our commitment to the world’s largest existing installed base and the future of the energy system

Our technologies enable efficient, cleaner electrification in the most reliable and responsible ways

Accelerating a clean energy transition with a range of solutions for solar, onshore and offshore wind

Our promise towards a carbon-neutral future

Advancing a sustainable energy future for all

Together with our customers and partners, we are co-creating global and local solutions to benefit society

Get in-depth insights on topics and trends in the energy sector from industry thought leaders

Join our electricity guru, Electron, in this animation series about the world of electricity and sustainable energy

Diversity and inclusion are the core of our success

        

Extra-high voltage (EHV) lines act as a 'backbone' for electricity transmission networks. Voltage surges due to lightning strikes and switching events put reliability of these EHV lines at risk. To meet this challenge, one of the leading power utilities in the USA selected Hitachi Energy's line surge arrester solution using Externally Gapped Line Arresters (EGLA).

Established in 1906, American Electric Power (AEP) is a major power utility in the United States. The company serves more than 5.5 million customers across a geographical area of more than 500,000 square kilometers. The high voltage power transmission network of AEP, running for over 63,000 kilometers and one of the longest in the US, includes extra-high voltage (EHV) lines, operating at voltages as high as 765 kilovolts (kV). These EHV lines facilitate the transfer of large amount of electricity over long distances.

Lightning strikes can result into excessive overvoltage stress across these lines. Such stress can damage assets of power transmission system, like transformers and switchgear, potentially leading to an interruption in electricity supply.

Hitachi Energy offered its PEXLINK line surge arrester concept as a solution to AEP to maintain reliability of EHV network. The solution uses an Externally Gapped Line Arrester (EGLA), with a disconnection device and remote monitor.

Hitachi Energy’s EGLA is designed as a universal solution with a compact, adaptable design suitable for installation on multiple types of transmission tower designs with minimal adjustment needed. The installation is fast and simple with proven, robust hardware. EGLA also includes an automatic overload disconnection and visual indication, making it easy to identify and replace a failed unit in time. It is possible to monitor EGLA from ground level, assuring personnel safety.