Blog

Hand function following accidental automatic animal syringe injector injuries | Scientific Reports

Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

Scientific Reports volume  12, Article number: 21061 (2022 ) Cite this article Veterinary Feeding Injection

Hand function following accidental automatic animal syringe injector injuries | Scientific Reports

Accidental self-injection injury is a common occurrence among veterinary and farm workers handling automatic syringe injectors. Most of the time, these injuries are asymptomatic or cause self-resolving mild symptoms, but these injuries may lead to significant morbidity. The aim of the study was to evaluate hand function after inadvertent injection of a poultry influenza or cholera vaccine in patients admitted to our department with infection. We retrospectively gathered data from admission to last follow-up. Functional assessment and physical exam of the hand were done at each stage by either an orthopedic resident or a fellowship-trained hand surgeon. The exam included evaluation of sensation using monofilament, joint range of motion using a goniometer, and a Quick DASH questionnaire. The study included 21 patients, all men, with a mean age of 33.4 years (range 23–44). Of the 21 patients only eight had attended all follow-ups. All patients had injury to the non-dominant hand. Seventeen of 21 of the cases had finger injuries, out of which 11 involved the thumb. The mean hospitalization time was 3.75 days (1–10). Of the 21 patients, seven underwent surgery to drain a collection during hospitalization. Seven out of eight patients had lowest disability scores on Quick Dash questionnaire. Three out of eight patients lost superficial sensation at the tip of the finger. The largest loss of range of motion was found in the distal interphalangeal joint in the finger or interphalangeal joint in the thumb, especially following surgical drainage. Of the eight patients presenting for follow-up, most had returned to the same job. Hand function was normal, as expressed in a DASH questionnaire. Sensory examination demonstrated that the sensation was almost unaffected over the injured finger. Range of motion of the joint closest to the injection site was usually the most impaired. Patients who underwent surgical drainage had a reduced range of motion.

Accidental self-injection injury is a common occurrence among veterinary and farm workers handling automatic syringe injectors (ASI), used in mass vaccinations of animals. In these populations, the lifetime occurrence of accidental injection during vaccination of an animal ranges from 64 to 93%. Incidence is probably much higher, as these injuries are usually not reported1,2,3,4,5,6. Fortunately, most of these injuries are asymptomatic or cause only mild, self-limited symptoms, but a portion of these injuries will lead to significant morbidity, including local and systemic consequences, such as infection7,8,9, soft tissue necrosis10, and the need for extensive surgical debridement or amputation of a digit11 (Fig. 1a,b).

(a,b) Index injection injury with collection prior to drainage following automatic syringe injector injury.

Similar to high-pressure injection injuries of the digit, seen in workers handling diesel injection apparatus or high-pressure paint sprayers, the severity of injuries is related to several variables including location, needle trajectory, secondary bacterial infection, and the type of inoculum12. ASI injuries usually involves the non-dominant hand13, Inexperienced male employees who have worked less than 6 months are at a higher risk of injury14.

Kaufman et al.15 dissected cadaver hands following a simulated pressure injection injury and mapped the pattern of anatomical spread of liquid material at various anatomical regions of the hand. He found that the injected liquid substance will spread in tissues until it encounters an impenetrable structure. He also stated that substances will rarely spread to the side of the injection trajectory. Tissues that resist penetration and spread of the liquid include bone, tendon, and flexor sheath. Hand anatomy is susceptible to these injuries, as it displays a lack of anatomical buffer zones, such as fat, and an abundance of terminal arteries and nerves, which can lead to increased morbidity in case of these injuries when compared to other areas of the body. ASI injuries are different than high-pressure injection injuries found in diesel and paint industries, which have higher finger amputations rates. Hogan and Ruland16 studied the outcome of high-pressure injuries and showed an overall amputation rate of 47% after finger injections, compared to 15% for the thumb and 25% for the dorsum of the hand.

The choice of antibiotic coverage is made empirically to cover common skin contaminants (Staphylococcus and Streptococcus), as well as organisms that may be present in the agricultural environment, including anaerobic bacteria and bacteria from the gram-negative family. Colonization of antibiotic-resistant organisms (methicillin resistant Staphylococcus aureus) is common in agricultural industry workers and thus should be considered when choosing antibiotic regimens in this population17.

We did not find any evidence of functional outcome documentation of ASI injuries in humans, but, in general, increasing the volume of injection in the finger compartment and the fact that the same needle is used repeatedly, and becomes contaminated with bacteria from the environment can lead to an increased risk of infection, necrosis and subsequent amputation14,18.

This clinical question of this study is whether the workers injured their hand from poultry influenza or cholera vaccine and admitted our department had functional deficit?

This is a retrospective descriptive study done between the years 2013 and 2021. This study was approved by the Emek medical center review bord (EMC 24-21), all methods were performed in accordance with the relevant guidelines and regulations. Patients admitted following ASI injury that occurred during poultry vaccination, containing either influenza or cholera vaccine were included. Our hypothesis was that admitted patients will have functional deficit due to this injury.

Data was retrospectively collected using computerized files, with information from admission to last follow-up collected. Functional assessment and physical examination of the hand were performed in each stage by either an orthopedic resident or a fellowship-trained hand surgeon. The examinations completed for available patients included evaluations of sensation using monofilament, joint range of motion using a goniometer, and the Quick DASH questionnaire (The QuickDASH tool uses a 5-point Likert scale from which the patient can select an appropriate number corresponding to his/her severity/function level)19.

Ethical approval to report these cases was obtained from the Emek medical center review bord (APPROVAL NUMBER/0120-21-EMC).

Written informed consent was obtained from the patient(s) for their anonymized information to be published in this article.

The authors have read the Journal's position on issues involved in ethical publication.

The study included 21 patients, all men, with a mean age of 33.4 years (range 23–44). Of the 21 patients, only eight had attended all follow-ups. Table 1 displays patient's demographics. All patients had injury to the non-dominant hand with no documentation of an old injury. Both volar and dorsal side of the hand were found. Seventeen of 21 of the cases had finger injuries, of which 11 involved the thumb.

The mean hospitalization time was 3.75 days (1–10). Of the 21 patients, seven underwent surgery to drain a collection during hospitalization (only one patient underwent two repeated procedures).

Of the seven patients who underwent surgery, only three had positive cultures. The latter is due to antibiotic treatment that preceded the surgical drainage. Cephazolin or Augmentin were used for empiric antibiotic treatment. Antibiotics were adjusted after obtaining susceptibility results (Table 2).

The average follow-up time was 11.7 months (3–29). Six of the eight patients returned to work, while two chose not to return to the same job for reasons unrelated to the injury. Seven out of eight patients achieved the lowest disability score on Quick Dash questionnaire. Only one patient presented a score of 36.4, indicating a minor disability of the hand. Three out of eight patients lost superficial sensation at the tip of the finger. Range of motion was measured with a goniometer for all injured finger joints. The metacarpophalangeal joint did not lose range of motion except for five degrees of flexion in two patients, the proximal interphalangeal joint lost 5 degrees of flexion in one patient, and the distal interphalangeal joint in the finger and the interphalangeal joint in the thumb both lost the most range of motion, especially following surgical drainage (between 5 to 45 degrees of flexion).

This study demonstrated, for the first time, the clinical outcomes in patients hospitalized after accidental injection injury to the fingers resulted from farm use of automatic syringe injectors. Previous studies have estimated that accidental injection injury is extremely common1,2,3,4,5,6, Leggat et al.3 reported a survey of 664 veterinarians with around three quarters (75.3%) reported suffering at least one NSI in the previous 12 months, while 58.9% reported suffering from at least one contaminated NSI during the previous 12 months. Weese et al.5 reported that 74% had experienced a needlestick injury during the preceding year. Nevertheless, according to current data, only a minority of cases develop local infections requiring antibiotic treatment, and of these cases, only a few require hospitalization for parenteral antibiotic treatment or surgery.

Vaccines for animals are rarely performed with single-use sterile needles. When mass vaccination of animals is done using an ASI, the same needle is used multiple times, compromising its sterility. Jenissan et al. documented a series of nine cases of accidental self-injection during animal vaccination. Five out of the patients developed infections requiring broad spectrum antibiotic treatment. In three individuals, empirical antibiotic treatment was needed due to infection with cellulitis, lymphangitis, and negative cultures. Two patients with infection had positive cultures for Streptococcus and Streptomyces, respectively13. Of our 21 patients, seven underwent surgery to drain a collection during hospitalization, and only three had positive cultures.

This study summarizes our experience with 21 patients over more than 8 years. The limitation of this study is its retrospective nature and the small number of patients that were available for long follow-up. This injury is common, the lifetime occurrence of accidental injection during vaccination of an animal ranges from 64 to 93%1,2,3,4,5,6, but the number of workers who have complication such an infection7,8,9 is very small and the evaluability of them in long follow-up is even smaller. Of the eight patients who did present for follow-up, most had returned to the same job. Hand function was normal as expressed in a DASH questionnaire. Sensory examination demonstrated that the sensation was almost unaffected over the injured finger. Range of motion of the joint closest to the injection site was usually most impaired. Patients who had drainage surgery had reduced range of motion.

The datasets used and/or analyzed during the current study available from the corresponding author on reasonable request.

Hafer, A., Langley, R., Morrow, M. & Tulis, J. Occupational hazards reported by swine veterinarians in the United States. J. Swine Health Prod. 4, 128–141 (1996).

Hill, D. J., Langley, R. L. & Morrow, W. M. Occupational injuries and illnesses reported by zoo veterinarians in the United States. J. Zoo Wildl. Med. 29(4), 371–385 (1998).

Leggat, P. A., Smith, D. R. & Speare, R. Exposure rate of needlestick and sharps injuries among Australian veterinarians. J. Occup. Med. Toxicol. 4, 25 (2009).

van Soest, E. M. & Fritschi, L. Occupational health risks in veterinary nursing: An exploratory study. Aust. Vet. J. 82(6), 346–350 (2004).

Weese, J. S. & Faires, M. A survey of needle handling practices and needlestick injuries in veterinary technicians. Can. Vet. J. 50(12), 1278–1282 (2009).

Wilkins, J. R. 3rd. & Bowman, M. E. Needlestick injuries among female veterinarians: Frequency, syringe contents and side-effects. Occup. Med. 47(8), 451–457 (1997).

Donham, K. J. & Thelin, A. Agricultural Medicine: Rural Occupational and Environmental Health, Safety, and Prevention 2nd edn. (Blackwell Press, 2016).

Jones, D. P. Accidental self inoculation with oil based veterinary vaccines. N. Z. Med. J. 109(1030), 363–365 (1996).

Patterson, C. J., LaVenture, M., Hurley, S. S. & Davis, J. P. Accidental self-inoculation with Mycobacterium paratuberculosis bacterin (Johne’s bacterin) by veterinarians in Wisconsin. J. Am. Vet. Med. Assoc. 192(9), 1197–1199 (1988).

Ogün, T. C., Uzümcü, A. U., Arazi, M. & Kapicioglu, M. I. Accidental Salmonella enteritidis vaccine injection leading to finger necrosis—A report of 4 cases. Acta Orthop. Scand. 70(6), 629–631 (1999).

O’Neill, J. K., Richards, S. W., Ricketts, D. M. & Patterson, M. H. The effects of injection of bovine vaccine into a human digit: A case report. Environ. Health 4, 21 (2005).

Feldman, G., Hitti, S., Rozen, N. & Rubin, G. Molten metal high pressure injection injury of the hand. Hand Surg. Rehabil. 39(4), 328–331 (2020).

Jennissen, C., Wallace, J., Donham, K., Rendell, D. & Brumby, S. Unintentional needlestick injuries in livestock production: A case series and review. J. Agromedicine 16(1), 58–71 (2011).

Couzens, G. & Burke, F. D. Veterinary high pressure injection injuries with inoculations for larger animals. J. Hand Surg. 20(4), 497–499 (1995).

Kaufman, H. D. The anatomy of experimentally produced high-pressure injection injuries of the hand. Br. J. Surg. 55(5), 340–344 (1968).

Hogan, C. J. & Ruland, R. T. High-pressure injection injuries to the upper extremity: A review of the literature. J. Orthop. Trauma 20(7), 503–511 (2006).

Smith, T. C. et al. Methicillin-resistant Staphylococcus aureus (MRSA) strain ST398 is present in midwestern U.S. swine and swine workers. PLoS ONE 4(1), e4258 (2009).

Kovachevich, R. & Kaplan, F. T. Animal injection injuries. J. Hand Surg. Am. 37(11), 2408–2411 (2012).

Hudak, P. L., Amadio, P. C. & Bombardier, C. Development of an upper extremity outcome measure: The DASH (disabilities of the arm, shoulder and hand) [corrected]. The Upper Extremity Collaborative Group (UECG). Am. J. Ind. Med. 29(6), 602–608 (1996).

Orthopedic Department, Emek Medical Center, Afula, Israel

Guy Rubin, Guy Feldman, Shtawe Shtawe & Nimrod Rozen

Faculty of Medicine, Technion, Haifa, Israel

Guy Rubin & Nimrod Rozen

You can also search for this author in PubMed  Google Scholar

You can also search for this author in PubMed  Google Scholar

You can also search for this author in PubMed  Google Scholar

You can also search for this author in PubMed  Google Scholar

G.R. and G.F. wrote the main manuscript text and S.S. N.R acquisition of data, analysis, and interpretation of data. All authors reviewed the manuscript.

The authors declare no competing interests.

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Rubin, G., Feldman, G., Shtawe, S. et al. Hand function following accidental automatic animal syringe injector injuries. Sci Rep 12, 21061 (2022). https://doi.org/10.1038/s41598-022-25641-0

DOI: https://doi.org/10.1038/s41598-022-25641-0

Anyone you share the following link with will be able to read this content:

Sorry, a shareable link is not currently available for this article.

Provided by the Springer Nature SharedIt content-sharing initiative

Scientific Reports (Sci Rep) ISSN 2045-2322 (online)

Hand function following accidental automatic animal syringe injector injuries | Scientific Reports

Adjatable Automatic Syringe Gun Sign up for the Nature Briefing newsletter — what matters in science, free to your inbox daily.