Fiber optics are a means of transmitting information at incredibly high speeds; however, the technology can be used for more than just providing a fast internet connection. Researchers reporting in ACS Sensors have developed an optical fiber sensing system that could help medical professionals monitor patients for complications after a traumatic brain injury. The technology tracks six biomarkers simultaneously, continuously and automatically to provide crucial information on brain health in lab tests.
After a traumatic brain injury, such as a concussion, secondary damage can occur from swelling in the brain. Biomarkers found in blood or spinal fluid provide medical professionals with information on brain health; however, many current methods struggle to monitor multiple biomarkers at the same time. So, Yuqian Zhang, Ali Yetisen and colleagues wanted to create an optical fiber system that concurrently monitors six key brain health biomarkers: temperature, pH, and concentrations of dissolved oxygen, glucose, sodium ions and calcium ions. Optical fibers, similar to the larger ones used in underground fiber optic cabling, are ideal for medical applications because of their small size and their ability to interact with light-absorbing biomarkers or tissues in measurable patterns. optical isolator
The researchers outfitted six optical fibers with fluorescent tips specific to each biomarker. A special multi-wavelength laser was shone through the fibers and used to monitor the analytes. When one target analyte interacted with a fluorescent tip, the change in brightness was recorded by a computer. Then the six fibers, along with an extra fiber to boost the calcium signal's measurement, were incorporated into a 2.5-millimeter-thick catheter to create a cerebrospinal fluid sensing system. Machine-learning-driven algorithms detangled the fluorescence signals from one another, providing an easy readout of each biomarker.
The catheter sensing system successfully detected the six biomarkers in an experiment with animal brains designed to mimic the conditions of the human brain after a traumatic injury. Next, cerebrospinal fluid samples were collected from healthy human participants and spiked with the brain health biomarkers of interest. The sensing system accurately determined pH, temperature and dissolved oxygen level in these samples and identified changes in the concentrations of the ions and glucose. The researchers say this work demonstrates that their optical fiber system can detect when a secondary injury might be imminent and could help monitor complications from these traumatic injuries in patients.
The authors acknowledge funding from the Royal Society, the National Natural Science Foundation of China and the China Scholarship Council.
Zhang, Y., et al. (2024) Fully Automated and AI-Assisted Optical Fiber Sensing System for Multiplexed and Continuous Brain Monitoring. ACS Sensors. doi.org/10.1021/acssensors.4c02126.
Posted in: Device / Technology News | Medical Science News | Medical Condition News
Tags: Analyte, Biomarker, Blood, Brain, Calcium, Catheter, Concussion, Education, Fluorescence, Glucose, Oxygen, pH, Research, Technology, Traumatic Brain Injury, Wavelength
Ijeoma Uchegbu discusses nanomedicine's role in improving medication adherence and developing non-addictive pain relief solutions at ELRIG Drug Discovery 2024.
Professor Nancy Ip discusses her groundbreaking neuroscience research, focusing on neurotrophic factors and innovative Alzheimer's disease treatment approaches.
Nimesh Khadka, Robin Nyland, Beatrice Sina
Learn about the usage of process raman spectroscopy in the optimization of bioreactor monitoring and then improvement of cultivated meat production.
News-Medical.Net provides this medical information service in accordance with these terms and conditions. Please note that medical information found on this website is designed to support, not to replace the relationship between patient and physician/doctor and the medical advice they may provide.
News-Medical.net - An AZoNetwork Site
Owned and operated by AZoNetwork, © 2000-2024
Your AI Powered Scientific Assistant
Hi, I'm Azthena, you can trust me to find commercial scientific answers from News-Medical.net.
To start a conversation, please log into your AZoProfile account first, or create a new account.
Registered members can chat with Azthena, request quotations, download pdf's, brochures and subscribe to our related newsletter content.
A few things you need to know before we start. Please read and accept to continue.
Please check the box above to proceed.
Azthena may occasionally provide inaccurate responses. Read the full terms.
While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.
Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.
Please do not ask questions that use sensitive or confidential information.
fiber cable installation Read the full Terms & Conditions.