Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

Scientific Reports volume  14, Article number: 10058 (2024 ) Cite this article Inductor 200uh

Magnetic integrated double-trap filter utilizing the mutual inductance for reducing current harmonics in high-speed railway traction inverters | Scientific Reports

Current harmonics are generated at the switching frequency and its multiples when the traction converters are modulated. To address this, multi-trap filters are introduced, which are capable of selectively eliminating these specific harmonics to the limits set by IEEE 519-2014. This targeted removal significantly reduces the need for high total inductance, thereby allowing for a more compact filter design. Comparatively, to traditional inductor-capacitor-inductor (LCL) filters, more magnetic cores are needed for trap inductors. Furthermore, the traction systems have not been examined in conjunction with multi-trap filters. To reduce the filter size and investigate its application in traction converters, this paper presents an integrated double-trap LCL (DTLCL) filter. A tiny capacitor is connected in parallel with the grid-side inductor to form one LC-trap. In addition, another LC-trap is formed by connecting the equivalent trap inductor, introduced through the magnetic coupling between inverter-side and grid-side inductors, in series with the filter capacitor. The presented filters' features are thoroughly analyzed, and the design method has been developed. Finally, the simulation and hardware-in-the-loop (HIL) experiment results validate the proposed method's viability and efficacy. Compared to the discrete windings, the integrated ones enable a size decrease of two cores. Furthermore, the proposed filters can meet IEEE 519-2014 criteria with 0.3% for all the current switching harmonics and total harmonic distortion (THD) of 2.36% of the grid‐side current.

Electric multiple units (EMUs) with pulse width modulation (PWM) traction inverters are often used on China's high-speed railway (HSR) lines1. For modern railway traction power-supply systems (TPSS), the undesired current harmonics produced by the modulating of traction inverters are a well-known issue2. These harmonics might result in a variety of issues that decrease the effectiveness of the traction networks, including severe faults and interruptions, torque bursts, and communications network disruptions3. In several electrical railways, harmonic resonance occurrences have led to the breakdown of high-voltage facilities, the improper initiation of protective systems, or perhaps locomotive traction bottlenecks4. Therefore, a major issue for HSR lines is mitigating and addressing the harmonic distortion. The high-frequency harmonics, especially at the switching frequency and its multiples, are attenuated utilizing passive filters5, although the harmonics at low frequencies might be mitigated by properly designed repeated controllers6 or proportional-resonant ones7. Whenever tied to the TPSS, traction inverters must adhere to the network regulations.

The high-frequency harmonics problem in HSR is frequently addressed using either the traction electric grid or the high-speed train (HST) drive units. The traction electric grid's harmonics reduction has received the majority of research attention. To change the harmonic impedance in the traction electrical network, several studies employ passive filters5. Capacitor (C) and inductor-capacitor (LC) filters are examples of these filters. The passive filter method becomes quite costly for TPSS with high voltage and large power. From the perspective of the HST drive unit, there exists an alternative way to reduce the harmonics generated by the traction PWM inverters. This way attenuates the HSR high-frequency harmonics by using the selective harmonic elimination (SHE) PWM mechanism in the traction inverter4. It has become clear that the offline optimal PWM approach had a low tolerance to the system parameters and required complex calculations to solve the basic equations. High-frequency harmonics may be easily absorbed with large filter inductors. Even yet, a straightforward approach such as this may essentially lead to an increase in the system's size, costs, and control bandwidths. Excluding a tiny additional capacitor utilized in the technique given in8, the well-known third-order LCL filters effectively replaced the conventional L ones with an identical overall inductance value. Nevertheless, it is hard to attain a wide control bandwidth, high power density, and good harmonic removal capacity, even with the LCL filter9.

Over the past few years, grid-connected inverters have increasingly used LCL filters to minimize high-frequency harmonics in the input or output current of renewable power plants10. The standard L-type boost inverter, in contrast, has been routinely utilized by the HSTs, particularly as a grid-side inverter. To satisfy the requirements for small size and light weight in HST systems, the traction transformer (TT) leakage inductor is often employed as an inductor of the grid-side inverter11. Several LCL-modified filter topologies are used in12,13,14,15,16,17,18,19,20,21,22,23. Several of those filters also include extra LC traps, which are resonant tanks that are parallel or in series, and resonate with the switching frequency and its multiples. Such traps may be used to bypass or block certain harmonics. Consequently, such harmonics are omitted from the current delivered into the network, the total harmonic distortion (THD) is reduced, and the capacitance and inductance of the filters are decreased.

When utilizing multiple traps that resonate at the switching frequency and its multiples, the harmonics eliminated by the trap-filters may be enhanced, and associated inductances can be reduced. Examples of these filters are LTL12,13,24,25, LTCL23,26,27,28, SPRLCL9, L(LCL)229, and PDTLCL30 filters, in which the letter "T" denotes one or more LC-traps. There is at least one LC-trap involved in each of these modified filters for bypassing or blocking selected harmonics. In general, the switching frequency and its multiples are the central amounts of switching harmonics. When these frequencies are matched to the LC-traps resonant frequencies, PWM harmonics may be significantly reduced. The inductance of trap inductors may also be highly tiny since the resonance frequency of LC-traps typically matches or exceeds the switching frequency, which further reduces the overall inductance. In addition, the switching harmonic currents of multilevel converters may also be considerably reduced by using filters with small inductances31.

The LTL filters, which are high-order trapped filters, have received significant attention. Parallel LC traps provide for improved harmonic attenuation. However, this may lead to increased trap inductances in these filters. According to actual applications, two LC traps are preferable since the prominent harmonics are concentrated around the switching frequency and its first multiple. However, it is hard to minimize the output filter because these filters still require two additional inductors compared to LCL filters, which occupy most of the volume in filter components. It is generally important to consider the size of a filter when designing it, as the size of the filter can impact its performance and overall effectiveness. In many cases, filter design aims to achieve the desired performance level while minimizing the filter's size as much as possible. There are several reasons why the size of a filter may be an important consideration, like cost, space constraints, weight, and power density.

Most past research has focused on reducing power filters' overall inductance to lower their expense and size. The total size of the power filters is primarily due to the magnetic cores. However, high-order trapped filters include extra magnetic cores that cause a significant increment in the system size, despite a considerable reduction in overall inductance. The most frequent solution for that problem is the magnetic integration approach, which integrates many discrete inductors onto a single magnetic core11,32,33,34,35,36,37,38. To increase the converter efficiency, an EIE-type core has been proposed in37,38 to magnetically integrate the LCL filter to minimize the core size. Three-phase LCL filters are presented in39 to be magnetically integrated using a delta-yoke composite core. This core is smaller than an EIE-type core by nearly 10%. Although decoupled core configurations like EIE and delta-yoke types are possible, magnetic integration always leads to magnetic coupling. The harmonic absorption of LCL filters is affected by the magnetic coupling, which introduces a coupling inductance into the filter capacitor branch. In the EIE-type magnetic core,40,41 used a good-permeable I-type core to reduce magnetic coupling impacts.

On the other hand,42,43 formed an LLCL filter based on the magnetic coupling inductance produced through the magnetic coupling. Nevertheless, a particular air gap must be placed into the shared flux channel of an EE-type core to get the appropriate trap inductor, which limits the design flexibility and causes parameter modification to be complicated after fabrication. Since42,43 only achieved one LC-trap, the filter has a low harmonic suppression capability. In44, an integrated doubled-trap LTL filter has been presented. However, it required an extra inductor between the two LC traps, air gaps at the side limbs, and a complex design.

A single-phase double-trap LCL (DTLCL)-type PWM inverter for HSTs is designed using the expertise gained from the network-tied rectifiers and filters of renewable energy technologies. The DTLCL filter consists of two traps, one with zero impedance at the resonant frequency and one with a large impedance at the resonant frequency, in addition to the inverter-side inductance. The traps in the proposed filter attenuate harmonics at the switching and double switching frequencies, which dominate current harmonics. So, since the filter tackles lower harmonics in the higher multiples of the switching frequency, the needed filter inductors may be lowered. To reduce the high-frequency harmonics, which could cause resonance in the TPSS, this filter is designed to take the place of the traditional L-type and LCL-type rectifiers.

The area required by the LCL filter also has to be reduced because of the space restriction of air-core inductors in HSTs, which is solved by the presented filter. This filter would meet the power quality criteria and be well-suited for the constrained spaces in locomotives, according to simulation and hardware-in-the-loop (HIL) testing results. The magnetic core is coiled with the inductors of the filter. An easy inductor design, high inductor linearity, and simplified implementation are advantages of the presented technique.

The proposed filter will be evaluated against traditional passive filters, specifically its corresponding discrete DTLCL (or SPRLCL), LCL, and L filters, to demonstrate its viability. Only three different passive filters, L, LCL, and integrated filtering inductors LCL filters8,11,45, were utilized to reduce harmonics in traction systems, based on the authors' experience. So, the comparison is limited to the designed filter and the LCL and L filters. Furthermore, comparing the integrated DTLCL filter to the discrete DTLCL one will be done to verify the effectiveness of magnetic integrated elements in the filter design.

Additionally, the proposed methodology is compared to the SHE technique46,47, which utilizes a control system to suppress specific harmonics in the voltage waveform without the need for a resonant trap. However, SHE is limited to offline computations and needs extensive lookup tables at low fundamental frequencies, as well as amplifying higher-order harmonics to eliminate lower-order ones31,48,49,50. In contrast, the proposed technique is relatively easy, capable of achieving similar results at low harmonics, and reduces switching losses while eliminating harmonic distortions and improving output waveforms. It should be noted that while SHE targets voltage harmonics, the proposed approach primarily addresses current harmonics, which indirectly enhances voltage waveform quality due to the intrinsic relationship between current and voltage in electrical systems. Furthermore, the LCL filter capacitor and the inductance generated by the coupling effect between the two inductors create a trap without the need for additional elements, and the utilization of one magnetic core for both inductors results in a smaller overall size and associated cost savings.

The contributions of this paper are listed below:

An integrated double-trap filter is designed, simulated, and validated.

A detailed analysis of the many inductors for magnetic integration has been presented.

The performance of the harmonics removal and size reduction has been utilized to validate the proposed methodology.

The application, which is, in this case, railway traction converters, can be extended to other grid-connected inverters/rectifiers, including industrial power systems, renewable energy systems, and building power systems.

Identification of the potential to integrate the DTLCL filter directly into transformers, suggesting a promising direction for future research to enhance system integration and efficiency.

In this paper, following the introduction, the basic theory and operation characteristics of the proposed integrated DTLCL filter are introduced in “System structure and magnetic circuit analysis”. “Designing and modeling of magnetic integrated DTLCL filter” presents the magnetic integration approach, then the optimal design method to reduce filter inductances is proposed. Simulation and HIL experimental results to verify the feasibility and effectiveness of the proposed design are described in “Simulation and HIL experimental validation”. Lastly, “Conclusion” concludes the paper.

The standard TPSS arrangement utilized in China's HSR is shown in Fig. 18. To provide the all-parallel autotransformer (AT)-fed network, the three-phase 220 kV network voltage is stepped down to 27.5 kV single-phase double-feeders within the power supply station. TTs could be connected using single-phase, V/v(V/x), Ynd11, and Scott, among other methods. The V/x-structure TT is used by Chinese and German HSR due to its excellent capacity utilization, easy wiring, and compliance with AT catenary systems1. The all-parallel AT-fed TPSS scheme is commonly used in HSR and massive trains throughout the world due to its advantages of extended power supply, minimal voltage drop, and electromagnetic compatibility32. The ATs, mounted at the AT substation or section post, are separated along the track by roughly 10 to 15 km. In the complex AT traction electricity network, the feeders, contact lines, protection lines, communications cables, rail, and integrated grounding cables are all considered multiconductor transmission lines.

Traction grid configuration of the power supply substation with EMU.

Figure 1 depicts an equivalent single-phase inverter driving setup for HST. The line-side converter at every HST's electric grid is made up of two PWM converters connected in parallel. Two interleaved single-phase two-level rectifiers are used in the power conversion step in Fig. 1 to reach a good current carrying capacity and power factor. As shown in1, the train converter is frequently two-level, several interlaced, two- or three-level. The whole paper uses two interleaved two-level PWM inverters and grid configurations of an all-parallel AT-fed EMU drive unit for analysis. There are, however, several other grid configurations and EMU kinds, as was already indicated. However, the results of the simulation and HIL experiments and the established rule of the researched filter apply to those other configurations, which opens up the possibility of multiple distinct lines of future study.

As this paper mainly focuses on the application of the magnetic integrated DTLCL filter, the detailed mathematical model of HSR and initial parameters are not shown here, which has previously been explored in research in1,2,5,8,51,52,53. For example, using the nodal admittance matrix, a uniform mathematical model of TPSS and China HST is presented in51. The HSR modeling can potentially affect the filtering effect of the integrated DTLCL filter. The modeling of the HSR system, including the power converters, power cables, and load, can affect the performance of the integrated DTLCL filter in several ways. For example, the impedance of the load and the power cables can influence the filter's resonant frequency, affecting its ability to attenuate harmonics.

Additionally, the type and level of nonlinearities presented in the HSR system can affect the harmonic content of the signals transmitted through the filter, which can also impact its performance. As described in Fig. 1, the integrated DTLCL filter is placed in the PWM-controlled train to suppress the harmonic generated by the traction converter since it is the origin of harmonics in the low voltage side of the TT. Therefore, the traction grid is seen from the filter as a typical linear element, with vgg representing the contact-line voltage in the train location, while the equivalent load is seen as a fixed resistance2,8,11,53. Thus, to simplify the analysis, the values of the EMUs' converter parameters affecting the filter design and performance are listed in “Designing and modeling of magnetic integrated DTLCL filter”. The different grid modeling affects the designed parameters and filtering effect of the integrated DTLCL filter. However, the design concept and work principle are the same. This analysis is also applicable to the other passive filters.

The harmonics assessment circuit illustration from the line-side traction converter to the traction electrical network is shown in Fig. 2. It is filtered by an integrated DTLCL filter. Here, a single integrated DTLCL converter is used to represent a typical single H-bridge configuration for analysis's sake. This approach is justified by the similarity and equivalent configuration of the two H-bridges in the system, allowing accurately predicting the harmonics reduction potential of the DTLCL filter in traction converters. Moreover, this research focuses on assessing the effectiveness of the magnetic integration of the DTLCL filter specifically in traction converter applications. Thus, by modeling only one of the similar H-bridges, it is aimed to streamline the analysis while ensuring that the findings are representative and applicable to both bridges given their equivalency. With a transformation ratio of 27.5/1.55, the TT may be regarded as a standard linear unit. The equivalent leakage inductor of the secondary side of the TT is represented by Ls as well. It needs to be noticed that this exact setup does not significantly limit the installation of trap filters. These filters may often be used in dc/ac or ac/dc generation systems, single- or three-phase, and standalone or grid-connected36. In this case, Cdc stands for the dc-link capacitor, Rdc for the equivalent load of a single integrated DTLCL-type rectifier on the traction inverter-motor drive system, and IRdc and ICdc for their currents. Four switches designated as S1–S4 that operate at fsw transform the dc-link voltage Vdc into ac voltage vin that contains harmonics at the dominating switching frequency 2fsw and its multiples54. The harmonics are concentrated around 2fsw when using a unipolar sinusoidal PWM (SPWM). Thus, 2fsw is the actual switching frequency. It is also important to remember that harmonics at the double and fourfold switching frequencies 2fsw and 4fsw are much more prominent than those at high switching frequencies, which have the most output current harmonics. For this reason, the total harmonics can be effectively decreased by eliminating the harmonics at 2fsw and 4fsw. In real situations, two LC-traps are favoured due to their lower expense and size, and this is the approach that is further investigated in this work. The TT might be viewed as a typical transformer. For creating the worst instability situation, the equivalent series resistors of the filter components are disregarded.

Single-phase H-bridge PWM traction inverter with an integrated DTLCL filter.

The inverter-side and grid-side inductors, Li and Lg, are connected in series. The voltages of the two inductors are vi and vg, respectively. Additionally, iil and igl are the currents flowing through the two inductors. Moreover, igc denotes the currents flowing through the capacitors Cg. At the same time, the inverter-side current, the grid-side current, and the dc bus current are represented by ii, ig, and Idc, respectively. A shunt filter capacitor Cf has been inserted at the connection point of Li and Lg. The voltage at this point is denoted by vf, whereas if represents the current passing the Cf. Moreover, vpcc denotes the voltage at the point of common coupling. At this point, the inverter is tied to the grid.

The filtration effectiveness of the passive filters can be considerably impacted by the traction grid conditions. The traction grid is assumed to be weak in this article's analysis, which means that the short circuit ratio is significantly low. As a result, the grid impedance may dramatically vary55. For the worst case of instability, the grid might be described as a typical voltage source with series grid inductance. Since the grid resistance would reduce the resonant peaks, the focus will only be on the impact of the grid inductance, denoted by Ls in Fig. 2. Moreover, when many converters operate simultaneously to share power, the corresponding grid inductance detected by one converter might be proportional to the number of converters. The impact of the grid impedance gets bigger when the number of converters rises35. According to43, increased Ls could weaken the resonance poles. It has been discovered as a result that the filter experiences minor transient variations before going back to its setpoint. Despite this, the system's dynamic reaction required a longer time compared to the stiff grid circumstances. This paper focuses primarily on the application of the magnetic integrated DTLCL filter, and thus does not consider the use of Ls as the filter inductor of the H-bridge for estimating size reduction. This aspect has been extensively covered in previous studies, such as11,32,56,57, which detail the integration of filtering inductors in traction transformers for harmonic suppression. Additionally, the independence of the proposed DTLCL filter from Ls aligns with its broader applicability across various power electronics-based systems. This includes scenarios in strong grid conditions where no significant inductance is present, underscoring the versatility and robustness of the filter in diverse operational environments.

This section will explore a detailed methodology for designing the presented magnetic integration approach of a DTLCL filter. The design concept of the passive filter inductors was discussed in detail throughout the relevant literature. In typical LCL filters, the grid-side and inverter-side inductors each have their dedicated inductor, which requires the fabrication of two inductors. Suppose two LC-traps are used for the SPRLCL filter9, i.e., the equivalent discrete filter to the integrated DTLCL one and the discrete DTLCL filter, as shown in “Integrated DTLCL filter's properties and filtering effectiveness”. In that case, it is necessary to fabricate one extra inductor and one extra capacitor in addition to the grid-side and inverter-side inductors. Thus, the discrete SPRLCL or DTLCL filter still suffers from large size and expense because of the need for one capacitor and one magnetic core for the trap inductor. This is the case even if the overall inductance is lower than typical LCL filters. Magnetic integration, which is an excellent technique that has previously been used in LCL40,41 and LLCL42,43 filters, is recommended for more improvement of the power density while saving expenses.

Using the LLCL filters' magnetic integration as a basis, Fig. 3a illustrates the magnetic integration for the DTLCL filter, where to avoid magnetic saturation, two air gaps are introduced in the side limbs, and one air gap is also put in the central limb of a closed magnetic circuit made up of two E-type magnetic cores. Additionally, the central limb's cross-section area is double that of the side limbs to prevent magnetic saturation. In reality, E-type cores with these sizes have often been produced for industrial purposes. The main parameters for building the filter inductor are, in general, the size and material of the magnetic core, the number of turns Ni and Ng, and the lengths of the central and side limbs air gaps lgc and lgs. Air gaps can be included to prevent magnetic saturation, although doing so reduces the magnetic permeability effectiveness, necessitating a large number of turns to produce the appropriate inductances. The magnetic circuit model is shown in Fig. 3b, but the reluctances of the yokes and limbs of the magnetic core are ignored since, in the magnetic circuit, the air-gap reluctances are so much bigger than the other ones. Ri, Rm, and Rg, i.e., the magnetic resistance of the three limbs, may therefore be expressed more simply as functions of the air-gap reluctances. It is necessary to assess the flux density to design the magnetic core of the integrated filter inductors. Figure 4 depicts the electric connection schematic for such a circuit. By winding Li and Lg on the side limbs with Ni and Ng, the coupling influence may be fully used to lower the filter size. In such a magnetic core, the Li and Lg windings are negatively coupled because the flux directions at the side limbs are opposite. The central concept of the presented magnetic integration is constructing a trap-inductor via the magnetic coupling between Li and Lg inductors called an active trap inductor.

Proposed magnetic integration of DTLCL filter. (a) Core configuration of the integrated inductors and (b) simplified magnetic circuit.

Circuit configuration of an integrated DTLCL filter.

In contrast, the other trap is formed by connecting a shunt capacitor Cg with Lg winding. In the proposed design, integrating Li and Lg introduces a coupling inductor for one of the two LC traps. Based on Fig. 3b, Φi refers to the flux generated by Li winding. In contrast, Φim and Φig are the fluxes generated by Li winding and flowing across the central limb and Lg winding, respectively, as described in Eq. (1), where the magnetic resistors of the three limbs can be referred to by Ri, Rm, and Rg, respectively35,36,43,44.

Lg winding also generates the flux Φg, where the fluxes generated by Lg and flowing across the central limb and Li winding are Φgm and Φgi, respectively, as described in Eq. (2)35,36,43,44.

Every inductor winding's total flux consists of the self-flux and the mutual flux. Then, Eq. (3) might be used to define Vi and Vg43,44. Moreover, they can be described, according to Eqs. (1)–(3), as in Eq. (4)36,43, where the self-inductances Li and Lg and the mutual inductances Mig and Mgi could be described as in Eq. (5)35,36,42,43.

As a note, Mig and Mgi are identical, and both could be written as Mig. It is apparent that the two inductors are coupling according to Eqs. (4) and (5), and the following could represent Vi and Vg42,43.

Based on Eq. (5), the self and mutual inductances are determined by the magnetic resistances that could be defined by Eq. (7). In this equation, lgs and lgc denote the side and central limbs' air gap lengths, and AS and AC represent the side and central limbs' cross-section areas, with AS = 1/2AC. Moreover, μ0 = 4π × 10−7 N/A2 refers to the air permeability 35,36,42,43,44. In the end, the self and mutual inductances are determined with Eq. (8) by putting Eq. (7) in Eq. (5)35,36,43. As illustrated in Eq. (9), the coupling coefficient kMig is a metric that quantifies the degree of mutual inductance between two coupled circuits represented as the ratio of the mutual inductance to the square root of the product of the self-inductances. Furthermore, it can be found that the coupling coefficient could be effectively tuned by varying the air gap lengths lgc and lgs, or their ratio lgc/lgs.

The proposed approach can accomplish the formation of one equivalent trap inductor by using the magnetic coupling between two windings, as seen in “Integrated DTLCL filter's properties and filtering effectiveness”. Consequently, it is possible to avoid needing two magnetic cores and decrease the expense and size of the DTLCL filter. Furthermore, it is observed that, in contrast to the discrete SPRLCL filter, there is no extra component.

Figure 4 depicts the circuit structure of the integrated DTLCL filter, consisting of an inverter-side inductance Li, in addition to two LC traps. These two LC‐traps (one is Mig–Cf and the other is Lg–Cg) are resonated to the dominant switching frequency 2fsw and its first multiple 4fsw because the harmonics are concentrated around 2fsw when using a unipolar sinusoidal PWM (SPWM), where, 2fsw is the actual switching frequency. The mutual inductor Mig is used in the integrated DTLCL filter for building a resonant trap with Cf. In contrast, Lg is used for creating another resonant trap with Cg for attenuating the switching harmonics. The resonance tanks eliminate the specific harmonics of the output current. At the same time, the other harmonics are attenuated by the whole filter. This paper proposes a method to design the integrated DTLCL filter by tuning the series resonant frequency to 2fsw and the parallel resonant frequency to 4fsw.

Moreover, the block diagram of the proposed filter is presented in Fig. 5. The transfer function GDTLCL(s) of the integrated DTLCL filter, from vin to ig, is calculated in Eq. (10), where the coefficients can be found in the Suppl. Appendix.

Block diagram of an integrated DTLCL filter.

The magnetic coupling is a key factor that has a great influence on the performance of the filter. According to Eq. (10), the mutual inductance is critical in calculating the transfer function for the overall system and, consequently, the frequency of the resonances and traps. By adjusting the mutual inductances, in other words, by tuning the coupling coefficients, these frequencies are effectively adjusted. Moreover, Eq. (9) demonstrates that the coupling coefficient may be effectively adjusted by changing the ratio lgs/lgc. Therefore, this ratio affects the transfer function of the whole plant, where this ratio is changed from around zero, i.e., lgs ≈ 0, to about infinity, i.e., lgc = 0. According to Eq. (8), it should be noted that lgs cannot be zero, but it can just be very little relative to lgc, while lgc can be zero. It can be stated that kMig values are inversely proportional to the lgs/lgc values. These values are changed from around one to about zero.

From Eq. (10), it can be found that GDTLCL(s) has two zeros at ωt1 = (1/(CfMig))1/2 and ωt2 = (1/(CgLg))1/2, respectively, where ωt1 and ωt2 represent the trap angular frequencies. The corresponding switching harmonics may be efficiently suppressed by setting those two frequencies to the dominant switching frequency, as indicated in Eqs. (11) and (12).‎ Moreover, the effectiveness of the proposed integrated DTLCL filter in reducing total harmonic distortion (THD) will be substantiated through simulation and HIL experimentation, as outlined in “Simulation and HIL experimental validation”.

The Bode diagrams ig(s)/vin(s) of the integrated DTLCL and discrete SPRLCL, LCL, and L filters are shown in Fig. 6 using the parameters depicted in Table 1. Section 3.1 goes into more depth about the steps taken to design these parameters. As Fig. 6 shows, the integrated DTLCL filter keeps the discrete SPRLCL filter's features and makes a strong harmonics suppression at 2fsw and 4fsw, where those two frequencies have two magnitude traps.

Bode diagrams for traction converters with integrated DTLCL and discrete SPRLCL, LCL, and L filters.

Furthermore, Fig. 6 shows that the magnitude-frequency characteristics of GDTLCL(s) have two conjugate resonant peaks because the degree of their denominator is 5. These resonant peaks are obtained by putting the denominator of GDTLCL(s) in Eq. (10) equals zero, substituting s with jω. The first resonFant frequency of the magnetic integrated DTLCL filter can be approximated as in Eq. (13)42,43, where ωres1 represents the resonant angular frequency and fres1 represents the resonant frequency.

As Fig. 6 shows, although the discrete LCL filter has the largest roll-off rate of −60 dB/dec at the high-frequency domains, it has no trap magnitude, which weakens its suppression in the switching frequencies. It is essential to design the second resonant frequency far off the switching frequency multiples to prevent the harmonics amplification26,35 and located around 2.5 kHz, as seen in Fig. 6 . After the second resonant frequency, the proposed integrated DTLCL filter has a harmonics suppression of −20 dB/dec.

The resonant peaks may cause system stability problems. Several damping approaches, including passive damping21,22,58, and active damping59,60,61,62,63, have been proposed to ensure system stability. Designing the resonant frequency beyond the Nyquist frequency is adopted because of the additional losses of passive dampening techniques and the great sensor expenses of active dampening techniques43,64. In addition, the parasitic filter resistances may offer excellent dampening for enhancing system stability and performance. Other works have previously done extensive stability analysis43,64. Therefore, it is not included here since this chapter emphasizes the magnetic integration of the DTLCL filter.

This part of the paper will explore a detailed methodology to design the DTLCL filter's parameters. The ac grid is assumed to be weak in the design process in this paper, with a grid inductance of Ls = 4 mH. This inductance value, along with other parameter values for the EMUs inverter listed in Table 2, is derived, with slight modifications, from empirical data used in references45,53,65. These references report the usage of similar or even higher values of Ls​ in comparable applications, specifically under conditions where a high series grid inductance is indispensable due to grid instability. The choice of Ls​, although appearing elevated for general applications, is meticulously selected to align with the realistic operational scenarios our study addresses and is substantiated by literature that investigates similar conditions of grid dynamics. The magnetic integrated DTLCL filter parameters might be designed by implementing the system parameters listed in Table 2 in light of the regulations of the harmonic suppression meets IEEE 519–20148,66,67, the consumed reactive power under 5%, and the inverter-side current ripple ΔILi less than 40%. Based on Rdc, the inverter functions as a rectifier here. Moreover, designing Li, which is based on the LCL filter's design method in8, is the first step in the design process of the magnetic integrated DTLCL filter. As a result, Li is designed as in (14) for a single-phase H-bridge unipolar SPWM inverter with ΔILi ≤ 40%, considering protecting the IGBTs and preventing saturation of the inverter-side inductor.

Because such a system can reach the lowest possible resonance frequency to accomplish the maximum amount of inductor utilization, the Lg design is equivalent to the Li design37,38,64,68. However, because the maximum current and ripple current have decreased by around 40%, Lg has been decreased to 1.3 mH.

To maintain the ac voltage drop in the inductors to less than 10% of the root-mean-square (RMS) value of vgg, the total inductance Ltotal = Li + Lg must be monitored9.

When selecting the capacitor Cf, the reactive power drawn at the fundamental frequency and harmonics elimination at high frequencies should be justified8,69. Cf may reach a small value like 125 µF while taking into account the permitted reactive power.

In addition, Mig is designed by satisfying Eqs. (11) and (13), i.e., fr1 of the magnetic integrated DTLCL filter is between 1/2fsw and 5/6fsw, while ft1 equals 2fsw, i.e., ft1 = 1.1 kHz. To improve stability and attenuate the reduction of inductance with increasing current, fr1 = 2/3fsw = 367 Hz was used as a midpoint value43,64. Consequently, Mig has been calculated as 0.167 mH.

Moreover, based on Eq. (9), the relevant coupling coefficient kMig is designed as 0.115 to adjust the second resonant frequency above 4fsw. As a result, lgs/lgc can be calculated to be 3.85, which proves that lgs determines Li and Lg.

The additional capacitor Cg is determined by Eq. (12), which can be derived as 4.619 µF. Nevertheless, to meet the power factor criterion, the total capacitance Ctotal = Cf + Cg must be constrained by the amount of reactive power consumed under the rated circumstances. furthermore, if Ctotal exceeded 0.05 p.u, the reactive current would be high8,64. The increase in filter inductance could help to solve this problem. Furthermore, Fig. 7 displays the elaborate design flowchart for the presented integrated DTLCL filter. This figure illustrates the flowchart of the design method as a general case, in which if one of the conditions is not fulfilled, the design process goes back to the first step. As for the inductance presented in Eq. (14) and other parameter values, they are presented as a design example to show the proposed filter design validity. In addition, according to the verification results, all the conditions are satisfied. Therefore, there is no need to go back to the first step of the design process. Furthermore, the designed parameters are slightly adjusted, and the presented ones are the final version.

Flowchart for the proposed integrated DTLCL filter design method.

In addition, the integrated inductors' power loss is minimized by using Litz wires with small ESRs and 0.5π mm2 cross-section area (Sω). The subsequent steps outline the design criteria for the suggested magnetic integration approach using the previously designed inductances. Choosing an EE-type magnetic core, along with its size and material, comes first. The saturation flux density Bsat, relative permeability μr, resistivity, and cost are typically considered when choosing a magnetic material. Higher Bsat or μr can reduce the number of turns of the inductor, which reduces the size and weight. In contrast, the eddy current losses can be lowered by higher resistivity. The magnetic material is chosen to compromise price, efficiency, size, and weight to get a cost-effective inductor. The well-known area-product approach70 may be used to choose the magnetic core's dimensions. The area-product (AP) of the cross-section and window areas (AS and AW) of Li is used to choose the magnetic core for the integrated windings. The EE magnetic cores are chosen depending on this technique70 with Li = 1.63 mH, inductor's maximum current Iil-max = 800 A, and maximum flux density of magnetic core Bmax = 0.35 T, where Bmax is set as λBsat with 0 < λ < 1, and Bsat is 0.49 T at 25 °C. λ is designed at 0.714 to guarantee a reasonable margin (30%). When the window area's utilization coefficient Ku = 0.5, AP = 11.71 × 10–6 m4, which may be calculated by Eq. (15).

Based on the NCD products catalog71, a pair of E 320/160/40 cores could be chosen, with AS = 1.66 × 10–3 m2 and AW = 18.84 × 10–3 m2, resulting in an area-product of 31.27 × 10–6 m4 ≈ 2AP, which leaves a large margin of size.

The SPRLCL filter would be designed by following the same procedure, implying that Li, Lg, and Cf equal those of the integrated DTLCL one for providing a reasonable assessment. The additional inductor Lf is determined by Eq. (11), replacing Mig with Lf, which is designed to be 0.167 mH. The additional capacitor Cg is determined by Eq. (12), with Mig = 0, which can be derived as 4.026 µF.

Using a similar technique, the LCL filter is designed, where Li, Lg, and Cf must be comparable to those of the proposed filter to offer a reliable evaluation.

Similarly, the L filter is set to match the Ltotal of the proposed filter because of the same purposes or equal the LCL filter by setting Cf = 0 μF.

After completing the design processes, all of the integrated DTLCL, discrete SPRLCL, LCL, and L filter parameters are provided in Table 1. In addition, the same controller implemented in36,43,45,48,53,65,72 may be used for the traction inverter with the integrated DTLCL filter, which is not discussed here. “Simulation and HIL experimental validation” will present the verification results for the proposed filter's design feasibility.

As noted, the proposed integrated double-trap filter can produce the equivalent additional inductor, thus saving one inductor with its components. In addition, the proposed magnetic integration can also save one magnetic core. This is because Li and Lg could be wound on the side limbs of one magnetic core instead of three magnetic cores like the discrete SPRLCL filter and other types like LTCL and LCL-LC filters.

The comparison between the sizes of integrated inductors and discrete ones is essential. The discrete inductors of the SPRLCL filter could be, respectively, coiled on the middle limbs of three cores. The filter inductances of the integrated DTLCL filter and the SPRLCL one are configured to be similar to ensure adequate comparison. The discrete SPRLCL filter has the most considerable size with three cores. In contrast, the discrete LCL filter has two cores, while the integrated DTLCL and discrete L filters have one core each.

To evaluate the performance of the proposed filter and design method, simulations using MATLAB/Simulink and HIL experiments were carried out on a traction inverter. The proposed filter could be validated by its comparison with the discrete SPRLCL, LCL, and L filters. The system's basic parameters used in the simulation and HIL experiments are described in Tables 1 and 2. With these parameters, verification models were constructed based on the system configurations shown in Fig. 2.

Analyses of the strengths and weaknesses, endurance, complexity, and size of several passive filters are conducted. The ability to attenuate harmonics and the transient performance of four filters are therefore examined using simulations and HIL testing. The several performance indexes that have been computed are listed in Table 3.

Figure 8a shows the simulated steady-state waveforms of ig, ii, vgg, and Vdc with the proposed integrated DTLCL filter. As can be seen, Vdc here approximates 3000 V, and the error is only 150 V (5%) owing to the control system's voltage loop. Furthermore, ig is well filtered in the steady state to be hugely sinusoidal. Figure 8b shows that its THD is just 2.36%, which is very low. A significant reason for this is the proposed DTLCL filter's ability to attenuate low-order harmonics and the double and fourfold switching-frequency harmonics to a combined attenuation of 0.01% and 0.00%, respectively. The harmonic currents on the grid-side inductor beyond 4fsw are also eliminated well, with sixfold switching-frequency harmonics of 0.04% of the fundamental current. From Fig. 8b, it is evident that there is a harmonic spike around 2.5 kHz that corresponds to the second resonance peak, confirming the theoretical analysis and Bode diagrams depicted in Fig. 6. In this case, all the harmonic currents can be limited to less than the limit of 0.3%, which complies with IEEE 519–2014 criteria. The switching harmonics composition is shown in Table 3.

Simulated results using the integrated DTLCL filter. (a) ii, ig, vgg, and Vdc waveforms, (b) ig and ii spectra.

Figure 9a illustrates the simulated waveforms of the traction inverter employing the discrete SPRLCL filter for comparative purposes. This part compares the performance of the proposed integrated filter and its discrete counterpart. Therefore, the same test has also ‎been conducted for the discrete SPRLCL filter, as ‎shown in Figs. 8 and 9. The waveform of ig retains sinusoidal when the integrated DTLCL filter is substituted with the discrete SPRLCL filter, demonstrating that the harmonics compensating at low frequencies would not be impacted. Furthermore, as illustrated in Fig. 9b, the 2fsw and 4fsw harmonics of ig are much reduced. The harmonics of ig over the fourfold switching frequency are also efficiently suppressed. The sixfold switching-frequency harmonics are 0.04% of the fundamental component, much lower than the limits. Here, it is also apparent that there is a harmonic spike around 2.5 kHz, which confirms the theoretical analysis and Bode diagrams shown in Fig. 6. Table 3 shows that the specified SPRLCL filter can meet IEEE criteria with a grid-side current THD of 2.12% but with bigger filter components. As demonstrated, the suggested filter, in general, performs similarly to the discrete SPRLCL filter, implying its effectiveness with a small size.

Simulated results using the discrete SPRLCL filter. (a) ii, ig, vgg, and Vdc waveforms, (b) ig and ii spectra.

Figure 10 shows the simulated results of the traction inverter filtered by the conventional LCL filter. The waveforms are shown in Fig. 10a, while the spectra of ig and ii are shown in Fig. 10b. As depicted in Fig. 10b, the third harmonic of ig exceeds the threshold of 4.00% of the fundamental component. This unipolar modulated traction inverter's somewhat inadequate performance can be attributed to its relatively low switching frequency and modest filter inductors. THD of ig is 4.34%, less than the permissible level. However, the discrete LCL filter requires two magnetic cores compared to one for the proposed filter.

Simulated results using the discrete LCL filter. (a) ii, ig, vgg, and Vdc waveforms, (b) ig and ii spectra.

The simulated results of the traction inverter with an L filter are shown in Fig. 11a. Only the simulated waveform of ig is shown since the waveform of ii is identical. This is due to the L filter being a series inductance; thus, ii and ig are essentially the same, making it redundant to plot both current waveforms. Although ig is filtered to a sinusoidal signal and in phase with vgg, a current spiking at the 39th harmonic, near 4fsw, is observed, as illustrated in Fig. 11b. This occurrence is due to the L filter’s limited ability to attenuate high-frequency harmonics, specifically at the dominant switching frequencies such as 2fsw and 4fsw, where the absence of a parallel LC-trap allows these harmonics to pass through the converter branch loop, which confirms the theoretical analysis and Bode diagrams shown in Fig. 6. As per IEEE Standard 519-2014, harmonics beyond the 35th order should be reduced to less than 0.3% of the nominal fundamental current. However, the 39th harmonic reaches approximately 0.4%, thus exceeding this limit and contributing to the non-compliance with grid regulations. The grid regulations are then broken. Moreover, Vdc will decrease to around 2560 V, leading to inadequate inverter operation and perhaps traction stoppage. A Vdc of 2560 V is not permitted in reality. Hence, additional investigation into this subject is recommended.

Simulated results using the discrete L filter. (a) ig, vgg, and Vdc waveforms, (b) ig spectrum.

Although this paper primarily focuses on the THDi and its implications for current harmonics, the voltage waveforms vgg and Vdc are included to provide a comprehensive view of the system behavior under different filtering conditions. The intrinsic relationship between current and voltage in electrical systems dictates that changes in current harmonics directly affect voltage quality. Given the critical role of voltage stability in traction inverter systems, which affects operational efficacy and system reliability, maintaining voltage waveform integrity is crucial. The observed decrease in Vdc, which can lead to traction stoppage, underscores the importance of these waveforms in the presented analysis in this paper.

From Table 3, although the THDs of the four filters, except the L one, are satisfied at less than 5%, the required inductance of the output filter differs. Moreover, the current switching harmonics of the first two filters at the LC-trap frequencies are nearly identical, proving the proposed approaches' validity. Furthermore, there are two magnetic cores saved compared to the discrete SPRLCL filter and one magnetic core in comparison with the discrete LCL one. Hence, the proposed filter reduces expenses and size.

Although the integrated DTLCL filter is smaller and lighter compared to the discrete SPRLCL and LCL ones, a thorough assessment must take the inductors' power loss into account. Because it is unstable, the L filter is not taken into consideration herein. The detailed analysis of the inductors' power losses, which has previously been explored in previous research43, is not included here since the primary focus of this paper is on the magnetic integration and application of the DTLCL filter in traction inverters. Inductors often lose power as a result of core and winding copper losses. Due to the numerous harmonics in ii and vi, the power loss of the inductors could not be computed or measured directly. To accurately evaluate the inductors' power loss of the integrated DTLCL, discrete SPRLCL, and LCL ones, the system efficiency is determined under similar circumstances. When performing under a unit factor, Pin denotes the input active power calculated using Pin = VggIgrms, while Po denotes the output active power calculated using Po = VdcIdc. The efficiency of the system is assessed using the ratio Po/Pin. The average values of idc and vdc that can be calculated or measured directly are Idc and Vdc. Igrms and Vgg are the RMS values of ig and vgg. The power loss is calculated by subtracting Po from Pin. The system efficiency of the integrated DTLCL and discrete SPRLCL and LCL ones under conditions equivalent to full load are 97.52%, 97.44%, and 97.37%, respectively. The efficiency is roughly equal to 97.3%, indicating low system power losses.

The load variation testing is performed on the proposed integrated DTLCL filter, where the related simulated waveforms are displayed in Fig. 12. At t = 0.8 s, the load was increased to 125% of its rated value (10 → 12.5 Ω). The capability of the filter to suppress instability, which is determined by going back to the setpoint, is the most crucial requirement in the transient state. As can be seen, the integrated DTLCL filter is strong enough to maintain stability even though the load varied by 25% in the transient duration. The dc-link voltage spike is lower than 300 V, and the total variation length was 0.12 s, followed by a smooth return to the setpoint, indicating a well-designed filter.

Simulated results using the integrated DTLCL filter with a step-up load variation of 2.5 Ω.

A 300 V step-down variation in Vdc (3000 → 2700 V) was performed at t = 0.8 s using the proposed integrated DTLCL filter to check the dynamic operation, where Fig. 13 shows the simulated waveforms. It is shown that before returning to the setpoint without fluctuating, the filter experiences a few transients. The system's dynamic responsiveness required a brief time until the current started following its reference, even though the transient phase lasted only for around 80 ms. As can be seen, the stability was preserved by the integrated DTLCL filter. Moreover, the proposed approach still demonstrates strong switching harmonics suppression abilities during the dynamic phase.

Dynamic simulated results using the integrated DTLCL filter.

Figures 12 and 13 show that the grid-side current is almost ringing-free. On the other hand, the system's dynamic responsiveness requests more time until the current follows the reference, leading to a longer dynamic period. According to the simulated results, because the integrated DTLCL filter has a sturdy construction, it is acceptable for traction networks.

For further verification, the experiments are also conducted on the HIL platform. The HIL experiments platform is set up to validate and test the presented filters' superiority, durability, and stability. The main advantage of the HIL experimental platform is that the real prototype may be evaluated without the need for underlying devices, as shown in Fig. 1473. Another advantage is that the designer need not depend on environmental or natural testing. Additionally, because the models could depict the plants, it is useful and economical. Using HIL, it is feasible to reduce the expense of physical validations in addition to the effort and time required for developing modifications in a wide range of situations74,75. Moreover, HIL experiments ease the recognition and redesigning barriers. In addition, it enables the real-time test to progress through the entire process more quickly than the physical test. Furthermore, HIL is preferable to physical tests in precision and expense since it can be designed and operated on a timetable.

HIL experimental platform's schematic diagram.

This method has shown considerable potential for business and academics thanks to HIL's ability to provide risk-free equipment and a speedy prototyping approach in research and engineering4,8,32,36,43,53,72,73,74,75,76,77,78,79,80,81. In cases when an extensive system is employed, HIL experiments may offer a secure testing environment. HIL is an attractive technique that offers the capabilities to test design methodology in a scenario of extensive systems with many complicated independent models that have high switching frequencies or quick dynamic behavior4,8,32,53,74,76,81. Furthermore, HIL is a contemporary technique frequently utilized for power electronic system testing and validation. To address the problems of difficulties, complexities, and expense, HIL has been used to assess power inverters73,75,77,78,79,80. The evaluation by HIL validation of the network-tied converter with passive filters is made more desirable, according to the results in8,32,36,43,72,77,78.

The presented filter is currently in the research phase, which must be clarified. Rather than the physical filter design that could happen in the subsequent phases, the presented filters would be created and evaluated utilizing the HIL platform during this phase since this is more cost-efficient and it is impossible to build an actual TPSS at laboratory tests. It is essential to note that the HIL technique is a powerful validation tool for new design techniques in large systems like TPSS since, with its help, it is possible to assess the accuracy and efficiency of the investigated systems without having to spend funds for their real implementation4,8,32,53,74,76,81. The standard method in the HIL technique is used in this study to represent the presented filters. Utilizing this standard method for the examined circuit, it is believed that the HIL technique offers relevant results that are extremely near to those of the real tests, as in the systems presented in8,32,36,43,72,77,78.

A fast control prototyping unit developed by StarSim modeling and integrated into the NI PXle-8821-FPGA-7868R real-time controller (RTC) and the NI PXle-8821-7846R real-time simulator (RTS) are all part of the HIL76, as shown in Fig. 15. The HIL also includes a power system emulating unit, hardware input/output ports, an oscilloscope, and a host computer. The translucent backboard of the NI PXle-1082 has eight slots and offers exceptional performance and output power. Moreover, HIL matches the OXI-5 PXI hardware requirements, has improved synchronization features, and delivers a high degree of reliability, leading to a low mean time for repairing75.

MATLAB/Simulink can be utilized for programming the control system, where the fixed-step solver can be used. Using the modeling program StarSim, the grid-connected rectifier with filter and control system models is uploaded into the HIL. Executing the grid-connected rectifier with filter model and control system model in RTS and RTC, respectively, results in constructing a closed loop. Like the simulation verification, identical parameters are used. The oscilloscope and monitor could be used for tracking the voltage and current waveforms. The oscilloscope may also provide data for the experimental current/voltage waveforms, which might then be uploaded to the MATLAB/Simulink program and examined with the Powergui FFT Analysis Tool.

Figure 16 depicts the experimental waveforms with the harmonic spectrum of ig of the integrated DTLCL filter. The controller causes Vdc to be close to 3000 V, and the error is only 150 V (5%). Additionally, ig is appropriately filtered to be extremely sinusoidal. Because of placing the two LC-traps at the frequencies of 1.1 and 2.2 kHz, the current switching harmonics were significantly decreased below 0.3% of the rated current, and the system meets the IEEE 519-2014 regulations.

For comparison, Fig. 17 shows the experimental results obtained using a discrete SPRLCL filter as a substitute for the proposed integrated DTLCL filter. The ig waveform maintains its sinusoidal shape, proving that the low-order harmonics compensation is unaffected. The double and four-fold switching frequency harmonics, which are the two prominent current switching harmonics, have been effectively diminished. Compared with Fig. 16, the performance of the proposed filter is often comparable to that of the discrete SPRLCL one, indicating that it is effective despite being small in size.

Experimental waveforms and grid-side current spectrum using the integrated DTLCL filter.

Experimental waveforms and grid-side current spectrum using the discrete SPRLCL filter.

Figure 18 illustrates the experimental waveforms and ig harmonic spectrum of the discrete LCL filter. The low-order harmonics of ig were found to nearly surpass the limits. This problem is caused by the low switching frequency of the unipolar modulated traction inverter and tiny filter inductors. Like the simulated results in Fig. 10, the THD of ig was seen as less than allowable levels.

Experimental waveforms and grid-side current spectrum using the discrete LCL filter.

Figure 19 depicts the experimental results of the conventional L filter. Although ig is filtered to a sinusoidal shape and in phase with vgg, a current spiking in the 39th harmonic, beside 4fsw, was observed, which is a breach of the network regulation. Furthermore, the Vdc decreased to around 2560 V, like the simulated results in Fig. 11. Consequently, this situation may lead to bad inverter performance or traction blocking. A 2560 V Vdc must not be allowed. As a result, additional research needs to look at the problem more thoroughly.

Experimental waveforms and grid-side current spectrum using the traditional L filter.

A step variation in the dc load occurred to investigate the system's transient performance of the integrated DTLCL filter. Figure 20 depicts the experimental results when the load gets a step change from 10 to 12.5 Ω at 0.8 s to evaluate the proposed filter's capacity to follow commands. As shown, the system can function appropriately in the face of transient occurrences, comparable to the simulation results in Fig. 12. The essential need in the transient state is the filter's capacity to suppress instability, which is assessed by returning to the setpoint. The integrated DTLCL filter is powerful enough to ensure stability even when the load varies. As observed, the dc-link voltage experienced a voltage rise before progressively dropping to the setpoint.

Experimental waveforms using the integrated DTLCL filter with 2.5Ω step-up variation to Rdc.

Next, the dynamic test was performed for the DTLCL filter, where Fig. 21 shows the experimental results of a 300 V step-down variation in the dc-link voltage. As can be observed, the waveforms are comparable to those simulated in Fig. 13, proving that the filter can provide both stability and switching harmonic attenuation. The DTLCL filter is seen to have certain transient moments and then return to its setpoint with no fluctuation, which verifies the system's robustness. Even though the transient phase only lasted for around 80 ms, the system's dynamic reaction needed a brief time till the current began following its reference.

Dynamic experimental waveforms using the integrated DTLCL filter.

All the experimental results are generally in agreement with the simulated ones and the theoretical analyses presented in the previous sections. These simulation and experiment results verify the theoretical analysis precision and confirm that the proposed integrated DTLCL filter keeps the advantages of the discrete SPRLCL and LCL filters and overcomes their disadvantages. The results show that the presented filter performs similarly to the discrete SPRLCL filter, the proposed parameter design approach is effective, and the proposed parameter robustness analysis technique is accurate. Furthermore, the integrated DTLCL filter has flexibility and performance under different working conditions.

A magnetic integrated double-trap filter, referred to as DTLCL, is proposed in this paper for traction rectifiers to lessen the inductors' size and weight because the space on high-speed trains is highly constrained while suppressing the dominating current switching harmonics. Based on traditional LCL filters, a tiny capacitor placed in parallel with the grid-side inductor could be used for constructing an LC-trap. Another LC-trap could be created by introducing the coupling inductance into the filter capacitor branch via the magnetic coupling of the inverter-side and grid-side windings. It is possible to tune these two LC traps to specific harmonic frequencies using a stepwise design method. The proposed filter can achieve the same harmonic suppression performance as the discrete double-trap filter, such as the SPRLCL filter, and save two magnetic cores of two trap inductors.

Furthermore, the presented filter has a magnetic core structure like the integrated LCL one but performs better in harmonic suppression. In addition, the resonance frequency is set over the Nyquist frequency, which equals half the sampling frequency, for using this design. The presented double-trap filter has been provided with a detailed step-by-step design method to facilitate the parameter choices. The developed filter could also withstand the grid impedance changes. After Simulink simulations and HIL experimental models were completed, the verification results were provided to demonstrate that the integrated DTLCL filter has the following advantages:

It has fewer discrete passive components than the discrete DTLCL and LCL filters.

Compared to other conventional passive filters, it effectively suppresses harmonics.

Flexibility in filter design and effectiveness of magnetic integration.

It has durability and stability to transient and dynamic occurrences.

The datasets generated and/or analysed during the current study are not publicly available due personal will but are available from the corresponding author on reasonable request.

Hu, H. et al. Overview of harmonic and resonance in railway electrification systems. IEEE Trans. Ind. Appl. 54(5), 5227–5245. https://doi.org/10.1109/TIA.2018.2813967 (2018).

Zhang, R., Lin, F., Yang, Z., Cao, H. & Liu, Y. A harmonic resonance suppression strategy for a high-speed railway traction power supply system with a SHE-PWM four-quadrant converter based on active-set secondary optimization. Energies. https://doi.org/10.3390/en10101567 (2017).

Kaleybar, H. J., Brenna, M., Foiadelli, F., Fazel, S. S. & Zaninelli, D. Power quality phenomena in electric railway power supply systems: An exhaustive framework and classification. Energies https://doi.org/10.3390/en13246662 (2020).

Cui, H., Song, W., Fang, H., Ge, X. & Feng, X. Resonant harmonic elimination pulse width modulation-based high-frequency resonance suppression of high-speed railways. IET Power Electron. 8(5), 735–742. https://doi.org/10.1049/iet-pel.2014.0204 (2015).

Hu, H., He, Z. & Gao, S. Passive filter design for China high-speed railway with considering harmonic resonance and characteristic harmonics. IEEE Trans. Power Deliv. 30(1), 505–514. https://doi.org/10.1109/TPWRD.2014.2359010 (2015).

Yang, S. et al. Circulating current suppression in modular multilevel converters with even-harmonic repetitive control. IEEE Trans. Ind. Appl. 54(1), 298–309. https://doi.org/10.1109/TIA.2017.2749257 (2018).

Seifi, K. & Moallem, M. An adaptive PR controller for synchronizing grid-connected inverters. IEEE Trans. Ind. Electron. 66(3), 2034–2043. https://doi.org/10.1109/TIE.2018.2838098 (2019).

Song, W., Jiao, S., Li, Y. W., Wang, J. & Huang, J. High-frequency harmonic resonance suppression in high-speed railway through single-phase traction converter with LCL filter. IEEE Trans. Transp. Electrif. 2(3), 347–356. https://doi.org/10.1109/TTE.2016.2584921 (2016).

Fang, J., Xiao, G., Yang, X. & Tang, Y. Parameter design of a novel series-parallel-resonant LCL filter for single-phase half-bridge active power filters. IEEE Trans. Power Electron. 32(1), 200–217. https://doi.org/10.1109/TPEL.2016.2532961 (2017).

Wu, W., Zhang, Y., Chung, H. S. H. & Blaabjerg, F. A new type of three-phase asymmetric-LCL power filter for grid-tied voltage source inverter with step-up transformer. IEEE Trans. Ind. Electron. 69(12), 11936–11945. https://doi.org/10.1109/TIE.2021.3131867 (2021).

Liu, Y. et al. A novel harmonic suppression traction transformer with integrated filtering inductors for railway systems. Energies 13(2), 1–18. https://doi.org/10.3390/en13020473 (2020).

Wu, F. et al. An LCPSL filter with multi-Tuned traps for grid-connected converters. In 2017 IEEE 18th Workshop on Control and Modeling for Power Electronics, COMPEL 2017. 1–7 https://doi.org/10.1109/COMPEL.2017.8013387 (2017).

Pan, D., Wang, X., Blaabjerg, F. & Gong, H. Active damping of LCL-filter resonance using a digital resonant-notch (biquad) filter. In 2018 20th European Conference on Power Electronics and Applications, EPE 2018 ECCE Europe. P.1–P.9 (2018).

Yao, W. et al. Phase reshaping via all-pass filters for robust LCL-filter active damping. IEEE Trans. Power Electron. 35(3), 3114–3126. https://doi.org/10.1109/TPEL.2019.2927272 (2020).

Zheng, C. et al. An integrated design approach for LCL-type inverter to improve its adaptation in weak grid. Energies https://doi.org/10.3390/en12132637 (2019).

Dragičević, T., Zheng, C., Rodriguez, J. & Blaabjerg, F. Robust quasi-predictive control of LCL-filtered grid converters. IEEE Trans. Power Electron. 35(2), 1934–1946. https://doi.org/10.1109/TPEL.2019.2916604 (2020).

Awal, M. A., Yu, H., Della Flora, L., Yu, W., Lukic, S. & Husain, I. Observer based admittance shaping for resonance damping in voltage source converters with LCL filter. In 2019 IEEE Energy Conversion Congress and Exposition, ECCE 2019. 4455–4462 https://doi.org/10.1109/ECCE.2019.8913194 (2019).

Pan, D., Ruan, X. & Wang, X. Direct realization of digital differentiators in discrete domain for active damping of LCL-type grid-connected inverter. IEEE Trans. Power Electron. 33(10), 8461–8473. https://doi.org/10.1109/TPEL.2017.2780174 (2018).

Tong, L., Chen, C. & Zhang, J. Iterative design method of LCL filter for grid-connected converter to achieve optimal filter parameter combination. J. Eng. 2019(16), 1532–1538. https://doi.org/10.1049/joe.2018.8824 (2019).

Saleem, M., Choi, K. Y. & Kim, R. Y. Resonance damping for an LCL filter type grid-connected inverter with active disturbance rejection control under grid impedance uncertainty. Int. J. Electr. Power Energy Syst. 109(1), 444–454. https://doi.org/10.1016/j.ijepes.2019.02.004 (2019).

Bian, S., Xu, J., Qian, Q. & Xie, S. Design and analysis of different passive damping for grid-connected LCL filters to achieve desirable system performance. In Proceedings—2018 IEEE International Power Electronics and Application Conference and Exposition, PEAC 2018. 1740–1745 https://doi.org/10.1109/PEAC.2018.8590359 (2018).

Beres, R. N., Wang, X., Blaabjerg, F., Liserre, M. & Bak, C. L. Optimal design of high-order passive-damped filters for grid-connected applications. IEEE Trans. Power Electron. 31(3), 2083–2098. https://doi.org/10.1109/TPEL.2015.2441299 (2016).

Xu, J., Bian, S., Qian, Q. & Xie, S. Stability-oriented design for LCL-LC-trap filters in grid-connected applications considering certain variation of grid impedance. In Proceedings-2018 IEEE International Power Electronics and Application Conference and Exposition, PEAC 2018. 1343–1348 https://doi.org/10.1109/PEAC.2018.8590452 (2018).

Wu, L., Liu, T. & Hao, X. Coordination control strategy for LLCL-filter based grid-tied inverter with indirect sliding mode power control and virtual impedance. J. Eng. 2019(16), 2804–2809. https://doi.org/10.1049/joe.2018.8506 (2019).

Huang, M., Wang, X., Loh, P. C. & Blaabjerg, F. LLCL-filtered grid converter with improved stability and robustness. IEEE Trans. Power Electron. 31(5), 3958–3967. https://doi.org/10.1109/TPEL.2015.2467185 (2016).

Li, F., Zhang, X., Zhu, H., Li, H. & Yu, C. An LCL-LC filter for grid-connected converter: Topology, parameter, and analysis. IEEE Trans. Power Electron. 30(9), 5067–5077. https://doi.org/10.1109/TPEL.2014.2367135 (2015).

Xu, J., Yang, J., Ye, J., Zhang, Z. & Shen, A. An LTCL filter for three-phase grid-connected converters. IEEE Trans. Power Electron. 29(8), 4322–4338. https://doi.org/10.1109/TPEL.2013.2292000 (2014).

Wu, W. et al. A new LCL-filter with in-series parallel resonant circuit for single-phase grid-tied inverter. IEEE Trans. Ind. Electron. 61(9), 4640–4644. https://doi.org/10.1109/TIE.2013.2293703 (2014).

Anzalchi, A., Moghaddami, M., Moghaddasi, A., Sarwat, A. I. & Rathore, A. K. A new topology of higher order power filter for single-phase grid-tied voltage-source inverters. IEEE Trans. Ind. Electron. 63(12), 7511–7522. https://doi.org/10.1109/TIE.2016.2594222 (2016).

Cheng, Z., Pei, L., Li, L., Wang, C. & Liu, J. Characteristics and design methods of new inverter output double-trap LCL filter for HS-PMSM drives. In 2021 24th International Conference on Electrical Machines and Systems (ICEMS). 1880–1885 https://doi.org/10.23919/icems52562.2021.9634633 (2021).

Sahoo, S. K. & Bhattacharya, T. Phase-shifted carrier-based synchronized sinusoidal PWM techniques for a cascaded H-bridge multilevel inverter. IEEE Trans. Power Electron. 33(1), 513–524. https://doi.org/10.1109/TPEL.2017.2669084 (2018).

Tong, N., Xu, J., Xiang, J., Liu, Y. & Kong, L. High-order harmonic elimination and resonance damping based on inductive-filtering transformer for electrified railway transportation system. IEEE Trans. Ind. Appl. 58(4), 5157–5170. https://doi.org/10.1109/tia.2022.3166722 (2022).

Gohil, F. B. G., Bede, L. & Teodorescu, R. Optimized integrated harmonic filter inductor for dual-converter-fed open-end transformer topology. IEEE Trans. Power Electron. 32(3), 1818–1831. https://doi.org/10.1109/TPEL.2016.2562679 (2017).

Jiang, S., Liu, Y., Ye, X. & Pan, X. Design of a fully integrated EMI filter for a single-phase grid-connected inverter. IEEE Trans. Ind. Electron. 68(12), 12296–12309. https://doi.org/10.1109/TIE.2020.3047049 (2021).

Fang, J., Li, X., Yang, X. & Tang, Y. An integrated trap-LCL filter with reduced current harmonics for grid-connected converters under weak grid conditions. IEEE Trans. Power Electron. 32(11), 8446–8457. https://doi.org/10.1109/TPEL.2017.2651152 (2017).

Al-Barashi, M., Liu, Z., Saeed, M. S. R. & Wu, S. Fully integrated TL-C-L filter for grid-connected converters to reduce current harmonics. In 2021 IEEE 12th Energy Conversion Congress and Exposition-Asia (ECCE-Asia) 1789–1794 https://doi.org/10.1109/ECCE-Asia49820.2021.9479097 (2021).

Xiaoqiang, L., Jingyang, F., Pengfeng, L. & Yi, T. A common magnetic integration method for single-phase LCL filters and LLCL filters. In 2017 IEEE Energy Conversion Congress and Exposition, ECCE 2017. 5595–5600 https://doi.org/10.1109/ECCE.2017.8096931 (2017).

Li, X., Fang, J., Lin, P. & Tang, Y. Active magnetic decoupling for improving the performance of integrated LCL-filters in grid-connected converters. IEEE Trans. Ind. Electron. 65(2), 1367–1376. https://doi.org/10.1109/TIE.2017.2733445 (2017).

Liu, Y., See, K. Y., Tseng, K. J., Simanjorang, R. & Lai, J. S. Magnetic integration of three-phase LCL filter with delta-yoke composite core. IEEE Trans. Power Electron. 32(5), 3835–3843. https://doi.org/10.1109/TPEL.2016.2583489 (2017).

Pan, D., Ruan, X., Bao, C., Li, W. & Wang, X. Magnetic integration of the LCL filter in grid-connected inverters. IEEE Trans. Power Electron. 29(4), 1573–1578. https://doi.org/10.1109/TPEL.2013.2281763 (2014).

Chen, F., Jiang, S., Jin, D. & Mei, Z. Magnetic integrated LCL filter design for a 2.5 kW three-phase grid-connected inverter with double closed-loop control. J. Power Electron. 22(2), 338–350. https://doi.org/10.1007/s43236-021-00365-y (2022).

Fang, J., Li, H. & Tang, Y. A magnetic integrated LLCL filter for grid-connected voltage-source converters. IEEE Trans. Power Electron. 32(3), 1725–1730. https://doi.org/10.1109/TPEL.2016.2613578 (2017).

Al-Barashi, M., Wu, S., Liu, Z., Meng, X. & Tasiu, I. A. Magnetic integrated LLCL filter with resonant frequency above Nyquist frequency. IET Power Electron. 15(13), 1409–1428. https://doi.org/10.1049/pel2.12313 (2022).

Li, X., Lin, P. & Tang, Y. Magnetic integration of LTL filter with two LC-traps for grid-connected power converters. IEEE J. Emerg. Sel. Top. Power Electron. 6(3), 1434–1446. https://doi.org/10.1109/JESTPE.2017.2764060 (2018).

Wu, S. & Liu, Z. Low-frequency stability analysis of vehicle-grid system with active power filter based on dq-frame impedance. IEEE Trans. Power Electron. 36(8), 9027–9040. https://doi.org/10.1109/TPEL.2021.3049145 (2021).

Memon, M. A., Mekhilef, S. & Mubin, M. Selective harmonic elimination in multilevel inverter using hybrid APSO algorithm. IET Power Electron. 11(10), 1673–1680. https://doi.org/10.1049/iet-pel.2017.0486 (2018).

Kundu, S., Bhowmick, S. & Banerjee, S. Improvement of power utilisation capability for a three-phase seven-level CHB inverter using an improved selective harmonic elimination-PWM scheme by sharing a desired proportion of power among the H-bridge cells. IET Power Electron. 12(12), 3242–3253. https://doi.org/10.1049/iet-pel.2018.5076 (2019).

Tasiu, I. A. et al. Review of recent control strategies for the traction converters in high-speed train. IEEE Trans. Transp. Electrif. 8(2), 2311–2333. https://doi.org/10.1109/tte.2022.3140470 (2022).

Ronanki, D. & Williamson, S. S. Modular multilevel converters for transportation electrification: Challenges and opportunities. IEEE Trans. Transp. Electrif. 4(2), 399–407. https://doi.org/10.1109/TTE.2018.2792330 (2018).

Priya, M., Ponnambalam, P. & Muralikumar, K. Modular-multilevel converter topologies and applications—A review. IET Power Electron. 12(2), 170–183. https://doi.org/10.1049/iet-pel.2018.5301 (2019).

He, Z., Hu, H., Zhang, Y. & Gao, S. Harmonic resonance assessment to traction power-supply system considering train model in China high-speed railway. IEEE Trans. Power Deliv. 29(4), 1735–1743. https://doi.org/10.1109/TPWRD.2013.2284233 (2014).

Song, K. et al. High-order harmonic resonances in traction power supplies: A review based on railway operational data, measurements, and experience. IEEE Trans. Power Electron. 35(3), 2501–2518. https://doi.org/10.1109/TPEL.2019.2928636 (2020).

Geng, Z., Liu, Z., Hu, X. & Liu, J. Low-frequency oscillation suppression of the vehicle–grid system in high-speed railways based on H∞ control. Energies 11(6), 1–23. https://doi.org/10.3390/en11061594 (2018).

Holmes, D. G. & Lipo, T. A. Pulse Width Modulation for Power Converters: Principles and Practice (Wiley Inc., 2003).

Lu, S., Xu, Z., Xiao, L., Jiang, W. & Bie, X. Evaluation and enhancement of control strategies for VSC stations under weak grid strengths. IEEE Trans. Power Syst. 33(2), 1836–1847. https://doi.org/10.1109/TPWRS.2017.2713703 (2018).

Tong, N., Xu, J. & Xiang, J. An inductive filtering-based traction transformer for high-order harmonic suppression of HS. In 2021 IEEE 4th International Electrical and Energy Conference (CIEEC). 1–7 https://doi.org/10.1109/CIEEC50170.2021.9510475 (2021).

Xiang, J. et al. Traction transformer integrated LCL filtering method for high-frequency harmonic and resonance suppression in AC train. Int. J. Electr. Power Energy Syst. 148(108922), 1–12. https://doi.org/10.1016/j.ijepes.2022.108922 (2023).

Xu, J. & Xie, S. LCL-resonance damping strategies for grid-connected inverters with LCL filters: A comprehensive review. J. Mod. Power Syst. Clean Energy 6(2), 292–305. https://doi.org/10.1007/s40565-017-0319-7 (2018).

Gaafar, M. A., Ahmed, E. M. & Shoyama, M. A two state feedback active damping strategy for the LCL filter resonance in grid-connected converters. J. Power Electron. 16(4), 1587–1597. https://doi.org/10.6113/JPE.2016.16.4.1587 (2016).

Wang, X., Blaabjerg, F. & Loh, P. C. Grid-current-feedback active damping for LCL resonance in grid-connected voltage-source converters. IEEE Trans. Power Electron. 31(1), 213–223. https://doi.org/10.1109/TPEL.2015.2411851 (2016).

Ben Said-Romdhane, M., Naouar, M. W., Slama-Belkhodja, I. & Monmasson, E. “Robust active damping methods for LCL filter-based grid-connected converters. IEEE Trans. Power Electron. 32(9), 6739–6750. https://doi.org/10.1109/TPEL.2016.2626290 (2017).

Roldan-Perez, J., Bueno, E. J., Peña-Alzola, R. & Rodriguez-Cabero, A. All-pass-filter-based active damping for VSCs with LCL filters connected to weak grids. IEEE Trans. Power Electron. 33(11), 9890–9901. https://doi.org/10.1109/TPEL.2017.2789218 (2018).

Liu, X. et al. Unified active damping control algorithm of inverter for LCL resonance and mechanical torsional vibration suppression. IEEE Trans. Ind. Electron. 69(7), 6611–6623. https://doi.org/10.1109/TIE.2021.3095796 (2021).

Tang, Y., Yao, W., Loh, P. C. & Blaabjerg, F. Design of LCL filters with LCL resonance frequencies beyond the Nyquist frequency for grid-connected converters. IEEE J. Emerg. Sel. Top. Power Electron. 4(1), 3–14. https://doi.org/10.1109/JESTPE.2015.2455042 (2016).

Wu, S., Liu, Z., Li, Z., Zhang, H. & Hu, X. Impedance modeling and stability analysis in vehicle-grid system with CHB-STATCOM. IEEE Trans. Power Syst. 35(4), 3026–3039. https://doi.org/10.1109/TPWRS.2020.2963897 (2020).

Assefa, S. A., Kebede, A. B. & Legese, D. Harmonic analysis of traction power supply system: Case study of Addis Ababa light rail transit. IET Electr. Syst. Transp. 11(4), 391–404. https://doi.org/10.1049/els2.12019 (2021).

IEEE Recommended Practice and Requirements for Harmonic Control in Electric Power Systems. Vol. 2014. (IEEE Standard 519-2014, 2014).

Tang, Y., Yoon, C., Zhu, R. & Blaabjerg, F. Generalized stability regions of current control for LCL-filtered grid-connected converters without passive or active damping. In 2015 IEEE Energy Conversion Congress and Exposition, ECCE 2015. 2040–2047 https://doi.org/10.1109/ECCE.2015.7309948 (2015).

Jayaraman, M. & Sreedevi, V. T. Power quality improvement in a cascaded multilevel inverter interfaced grid connected system using a modified inductive-capacitive-inductive filter with reduced power loss and improved harmonic attenuation. Energies 10(11), 1–23. https://doi.org/10.3390/en10111834 (2017).

Erickson, R. W. & Maksimovic, D. Fundamentals of Power Electronics 3rd edn. (Springer, 2020).

Soft Ferrite Cores. (Nanjing New Conda Magnetic Industrial Co. Ltd, 2020).

Al-Barashi, M. et al. Enhancing power quality of high-speed railway traction converters by fully integrated T-LCL filter. IET Power Electron. 16(5), 699–714. https://doi.org/10.1049/pel2.12415 (2023).

Liu, C. et al. A network analysis modeling method of the power electronic converter for hardware-in-the-loop application. IEEE Trans. Transp. Electrif. 5(3), 650–658. https://doi.org/10.1109/TTE.2019.2932959 (2019).

Tasiu, I. A. et al. Fuzzy observer-based control for the traction dual rectifiers in high-speed train. IEEE Trans. Veh. Technol. 70(1), 303–318. https://doi.org/10.1109/TVT.2020.3047663 (2021).

Zhu, L., Jiang, D., Qu, R., Tolbert, L. M. & Li, Q. Design of power hardware-in-the-loop simulations for integrated starter-generator systems. IEEE Trans. Transp. Electrif. 5(1), 80–92. https://doi.org/10.1109/TTE.2018.2881052 (2019).

Liu, C. et al. A system-level FPGA-based hardware-in-the-loop test of high-speed train. IEEE Trans. Transp. Electrif. 4(4), 912–921. https://doi.org/10.1109/TTE.2018.2866696 (2018).

Feng, F., Fang, J., Manandhar, U., Gooi, H. & Xie, P. Impedance-based stability analysis of DAB converters with single-, double-, or cooperative triple-phase-shift modulations and input LC filter. Front. Energy Res. 10, 1–12. https://doi.org/10.3389/fenrg.2022.874477 (2022).

Busarello, T. D. C., Guerreiro, J. F., Simoes, M. G., & Pomilio, J. A. Hardware-in-the-loop experimental setup of a LCL-filtered grid-connected inverter with digital proportional-resonant current controller. In 2021 IEEE 22nd Workshop on Control and Modelling of Power Electronics, COMPEL 2021. 1–8 https://doi.org/10.1109/COMPEL52922.2021.9646047 (2021).

Zeni, V. S., Munaretto, L., Chaves, H., Dal Pont, N. C., Gruner, V. F. & Finamor, G. Hardware-in-the-loop simulation of smart hybrid inverter: a comparison of online simulation and practical results. In Conference Record of the IEEE Photovoltaic Specialists Conference. 2005–2009 https://doi.org/10.1109/PVSC45281.2020.9300809 (2020).

Alvarez-gonzalez, F., Griffo, A., Sen, B. & Wang, J. Real-time hardware-in-the-loop simulation of permanent-magnet synchronous motor drives under stator faults. IEEE Trans. Ind. Electron. 64(9), 6960–6969. https://doi.org/10.1109/TIE.2017.2688969 (2017).

Amin M. & Abdel Aziz, G. A. A hardware-in-the-loop realization of a robust discrete-time current control of PMa-SynRM for aerospace vehicle application. IEEE J. Emerg. Sel. Top. POWER Electron. 7(2), 936–945 https://doi.org/10.1109/JESTPE.2018.2890592 (2019).

School of Aeronautics and Astronautics, Guilin University of Aerospace Technology, Guilin, 541004, China

Maged Al-Barashi, Yongjun Wang & Bin Lan

School of Automobile Engineering, Guilin University of Aerospace Technology, Guilin, 541004, China

You can also search for this author in PubMed  Google Scholar

You can also search for this author in PubMed  Google Scholar

You can also search for this author in PubMed  Google Scholar

You can also search for this author in PubMed  Google Scholar

Conceptualization, M.B.; methodology, M.B.; software, M.B. and M.S.; validation, M.B.; formal analysis, M.B. and Y.W.; investigation, M.B.; resources, M.B.; data ‎curation, M.B. and B.L.; writing—original draft preparation, M.B.; writing—review and editing, M.B.; visualization, M.B.; supervision, Y.W.; project administration, Y.W.; funding acquisition, Y.W.. All authors reviewed the manuscript.

The authors declare no competing interests.

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Al-Barashi, M., Wang, Y., Lan, B. et al. Magnetic integrated double-trap filter utilizing the mutual inductance for reducing current harmonics in high-speed railway traction inverters. Sci Rep 14, 10058 (2024). https://doi.org/10.1038/s41598-024-60877-y

DOI: https://doi.org/10.1038/s41598-024-60877-y

Anyone you share the following link with will be able to read this content:

Sorry, a shareable link is not currently available for this article.

Provided by the Springer Nature SharedIt content-sharing initiative

By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.

Magnetic integrated double-trap filter utilizing the mutual inductance for reducing current harmonics in high-speed railway traction inverters | Scientific Reports

470uh Inductor Smd Scientific Reports (Sci Rep) ISSN 2045-2322 (online)