Continuous input current buck DC/DC converter for small-size wind energy systems featuring current sensorless MPPT control | Scientific Reports

Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

Scientific Reports volume  14, Article number: 380 (2024 ) Cite this article electric capacitor for improving power factor of induction heating

For decentralized electrification in remote areas, small-sized wind energy systems (WESs) are considered sustainable and affordable solution when employing an efficient, small-sized component converter integrated with a less-sophisticated, cost-effective MPPT controller. Unfortunately, using a conventional buck DC/DC converter as a MPP tracker suffer from input current discontinuity. The latter results in high ripples in the tracked rectified wind power which reduces the captured power and affects system operation especially in standalone applications which are self-sufficient and independent of grid support. Furthermore, these ripples propagate to the machine side causing vibration and torque stress which impacts turbine performance and safety. To solve this issue, a large electrolytic capacitor is placed at the buck converter input to buffer these ripples, yet at the cost of larger size, losses and reduced reliability. Oppositely, the developed C1, D4 and D6 buck converters have the merit of continuous input current at small component-size. In this paper, dynamic modelling of these three converters is developed to select the one with the least input current ripples to replace the traditional buck converter in the considered WES system. Consequently, fluctuations in the tracked power are minimized and the large buffer capacitor is eliminated. This enhances system lifetime, reduces its cost and increases tracking efficiency. Moreover, mechanical power and torque fluctuations are minimized, thus maintaining machine protection. Furthermore, a sensorless MPPT algorithm, based on converter averaged state-space model, is proposed. Being dependent on variable-step P&O algorithm, the proposed approach features simple structure, ease of control and a compromise between tracking time and accuracy besides reduced cost due to the eliminated current sensor. Simulation results verified the effectiveness of the selected converter applying the proposed MPPT approach to efficiently track the wind power under wind variations with cost-effective realization.

Owing to increasing energy demand, diminishing nature of fossil-fuel sources besides their environmental concerns, power generation from renewable energy sources (RESs) is gaining much interest nowadays1. Among various RES, wind energy, when being used to produce electric power from wind turbines, is considered one of the dispersed energy alternatives with the fastest expanding market due to its abundancy, low-cost production and minimal impact to environment2.

However, with its intermittent nature due to wind speed variations, capturing the most energy possible from wind energy conversion systems (WECSs) must be ensured3. This implies continuous tracking to the maximum power via an efficient maximum power point tracking (MPPT) algorithm realized by a reliable converter configuration4. To this end, a number of MPPT techniques have been developed and effectively implemented5,6,7,8,9,10,11. These methods can be classified into four main categories; direct power control (DPC), indirect power control (IPC), smart and hybrid techniques, yet each has its own advantages and limitations. Since MPPT techniques differ in many aspects (implementation complexity, accuracy, tracking speed, number of sensors, parameters dependence and prior knowledge requirement, etc.), selecting the most convenient MPPT scheme is application and system-size dependent12.

For standalone electrification applications in remote areas where grid access is expensive or unavailable, off-grid small-size WESs are considered one of the cost-effective solutions in locations where wind energy is abundant12,13. Yet, some challenging aspects should be considered to maintain high reliability, minimal complexity and reduced cost of the considered decentralized WES.

The first aspect, is the generator used in the WECS. There are various kinds of generators employed for the WES where squirrel cage induction generator (IG), doubly-fed IG and permanent magnet synchronous generator (PMSG) are the most popular ones14,15. Due to their high-power density, gearless operation and direct drive construction, PMSG-based WESs are an excellent candidate16. Moreover, their cost-effectiveness, higher reliability and efficiency, full controllability range and better fault ride-through capability make them more favorable than their counterpart17. Finally, being dependent on permanent magnets rather than separate excitation systems, PMSGs show more flexibility for full scale conversion.

Another challenging aspect is the applied power conversion topology. As previously discussed, wind turbines must extract the most power possible from the available wind at any given wind speed. The pitch angle of the wind turbine blade can be controlled by pitch control as one means of achieving this goal, although due to the mechanical design of small wind turbines, pitch control is somewhat problematic18. Therefore, achieving electrical MPPT via power conversion stages are preferable for small-scale wind turbines19. A passive rectifier is used with PMSG WES for low-power applications along with a DC–DC converter as a more affordable solution to control generator output power18,19. This DC/DC converter is responsible for the MPPT process and its performance is affected by electrical and control concerns. For a lower DC voltage level, the buck converter is a popular design especially for decentralized WECS20. However, typical buck converters exhibit significant limitations due to their discontinuous input current inherited feature21. Thus, when utilized as a MPP tracker in WES, this will result in significant tracked power ripples, thus deteriorating the MPPT process and reducing its efficiency22. Moreover, this is reflected on large turbine mechanical power and torque fluctuations causing harmful torque stresses which can greatly affect turbine performance and safety in standalone operation23. To solve this issue, a large electrolytic capacitor is placed between the rectifier output and the buck converter input to act as buffer for these fluctuations yet at the cost increasing converter size, reducing its lifetime as well as imposing electrical resonance difficulties22. Fortunately, in21, three buck DC/DC converter topologies (C1, D4 and D6) that provide continuous input continuous output (CICO) operation have been proposed. These converters would draw a regulated, ripple-free input current24, resulting in minimal tracked power ripples and meanwhile eliminate the need for buffer capacitor, thus improving system reliability and reducing its complexity, size and cost25.

Finally, employing an efficient, simple and low-cost MPPT algorithm is a further challenge facing standalone small-size WECSs which are considered in this work26. P&O search scheme is an appealing candidate, especially for low-power applications, since it requires only voltage and current sensors, rather than mechanical sensors, to compute changes in the tracked power and determine the perturbation direction27. This reduces system cost, size and implementation complexity; thus P&O is frequently deployed in commercial freestanding small-size WECSs using inexpensive microprocessors28. Despite its simple implementation and satisfactory performance, conventional fixed step-size P&O algorithm forces the operating point to oscillate about the MPP during rapid wind changes, which leads to high power fluctuations27. Hence, this limitation was addressed by replacing the constant step-size by a variable one to compromise between tracking accuracy and speed7.

In this paper, it is proposed to employ a continuous input current buck converter in a standalone WES, rather than the traditional buck converter, to eliminate the buffer capacitor and yet minimize tracked power ripples. To assess the three CICO buck converters (C1, D4 and D6) introduced in21 and select the one with least input current ripples, detailed average models are derived for each of the three converters. According to derived equations, D6 was witnessed to attain the least input current ripples i.e. highest tracking efficiency, thus will be considered in simulation work. Moreover, a current sensorless MPPT method, featuring variable-step P&O scheme, is proposed to be implemented by the selected converter to add to system simplicity and reduced cost. In summary, this paper proposes a cost-effective standalone PMSG-based WECS with the following merits;

D6 DC/DC buck converter is applied as the MPP tracker with its continuous input current integrated capability and minimal input current ripples, thus minimizing input power ripples and maximizing tracking efficiency at the least possible component count.

The buffer large electrolytic capacitor between the rectifier and converter stage is eliminated thus reducing system size and enhancing its lifetime and reliability.

A current sensorless MPPT scheme is proposed which estimates the converter input current based on the state-space model of the selected D6 converter, thus reducing system size and cost

Being dependent on variable-step P&O algorithm, the proposed MPPT scheme features the merits of simple realization, absence of any mechanical sensors and enhanced compromise between tracking time and accuracy as well as further reduction in size and cost due to the eliminated current sensor.

The proposed topology functionality was tested and validated using MATLAB/Simulink. The simulation findings confirmed that when utilized with WESs, D6 outperforms the standard buck converter; achieving minimal mechanical and electrical power oscillations while removing the large buffer capacitor. Moreover, the functionality of the proposed current sensorless MPPT controller is also verified during wind variations with a single voltage sensor rather the voltage and current sensors required by the conventional sensored controller.

Hereby, the system under consideration, shown in Fig. 1, is discussed in details14. It is an off-grid WECS that comprises a wind turbine, a gearless Permanent Magnet Synchronous Generator (PMSG), a passive diode rectifier and a DC/DC converter that bucks the generator rectified voltage to the required DC level and meanwhile acts as the MPP tracker. Table 1 shows considered system parameters.

The mechanical power delivered by a wind turbine (WT), given ideal blades with perpendicular air flow to the rotational plane of the wind turbine, is calculated as follows14,29;

where ρ is the air density in kg/m3, R is the turbine blade radius in m, vw is the wind velocity striking the turbine blades in m/s and CP is the turbine power coefficient.

It is worth noting that CP measures the conversion efficiency of the turbine power i.e. the percentage of power that can be extracted by the WT and is limited by less than 59% as given by Betz limit30. As noted in Eq. (1), CP depends on λ and β which are the tip speed ratio and blade pitch angle respectively. λ can be computed from Eq. (2) as follows;

where ω is the wind turbine angular mechanical speed in rad/s.

Figure 2 gives the characteristic curves of harvested mechanical power from the considered WES versus WT speed for different wind speeds. It is clear the that, for each wind speed, there is an optimal power point at which the WT is forced to operate using a MPPT algorithm to extract the available peak power and maximize system efficiency.

Turbine ω-P curves for different wind speeds.

After harvesting the maximum mechanical power, the latter is used to drive a generator to produce the required electrical energy. Due to their high-power density, high efficiency, and direct drive construction, PMSG-based WESs are an excellent candidate providing a reliable, cost-effective solution16,17. For successful control of generator output power in PMSG-based low-power WESs, a passive rectifier stage followed by a DC-DC converter stage is found to be a more affordable solution18,19.

Considering two axis Park’s theory, the state equations governing the PMSG conventional d–q model are driven from Fig. 3 as follows31;

where \({{i}_{sd, }i}_{sq}\) are the d-axis and q-axis stator currents respectively, \({R}_{sa}\) is the stator resistance, \({\omega }_{s}\)   is the electrical angular frequency of the generator;  \({{L}_{sd, }L}_{sq}\)  are the stator inductances of generator in the d-axis and q-axis respectively; \({\varphi }_{p}\) is the permanent flux and  \({{v}_{sd, }v}_{sq}\) are the d-axis and q-axis stator voltages respectively.

Conventional d–q coordinate frame of PMSG model: (a) d-axis circuit; (b) q-axis circuit31.

The electromagnetic torque in the rotor (\({T}_{e}\) ) is given by;

where p is the number of poles.

A full-wave bridge rectifier is applied at the generator output to convert its output AC voltage into rectified DC voltage \(({V}_{r})\) which is the input voltage \(({V}_{i})\) to the following buck converter stage. The rectified DC voltage is computed from Eq. (6) as follows32;

where \({V}_{LL}\) is the effective value of the rectifier line-to-line input voltage.

For the considered system, a buck DC/DC converter stage is added after the rectifier stage to step-down the rectifier output DC voltage to the required DC bus level. Meanwhile the switching of this DC/DC converter stage is controlled to extract the maximum available power at the rectifier output, thus this converter is considered the MPP tracker in the considered system. Conventionally, a traditional buck converter is applied as the MPPT tracker whose switching is controlled via conventional fixed-step P&O MPPT technique.

Modeling of conventional buck converter is first carried without employing the input buffer capacitor to verify the buck integrated feature of discontinuous input current. Then, it is modelled again when applying a buffer capacitor at the buck converter input to emphasize this capacitor importance to buffer enlarged input current ripples and minimize their propagation to the machine side when using the buck converter as a MPP tracker in RES applications33.

For each case, the converter average model is originated, in continuous inductor current mode, using Fig. 4a and b, to compute voltage and current gains, capacitor ripples voltage ripples \(\Delta {{\varvec{v}}}_{{\varvec{C}}}\) , inductor current ripples \(\Delta {i}_{L}\) and converter input and output current ripples \(\Delta {i}_{i}, \Delta {i}_{o}\) as shown below. It is worth noting that normally in the buck converter model an output capacitor is placed to filter the obtained output voltage, however, since in the considered application a DC bus or microgrid is considered, thus there is no need for an output capacitor.

Circuit topology and switching modes for conventional buck converter (a) without Ci, (b) with Ci.

To find voltage and current transfer functions;

The average inductor voltage VL = 0,

Average input power Pi = Average output power Po,

where Vi and Vo are the converter input and output voltages respectively, Ii and Io are the converter input and output currents respectively and D is the converter duty ratio.

To find voltage and current ripples;

For Case I (without Ci);

When the switch S is closed;

where fsw is the converter switching frequency.

For Case II (with Ci);

When the switch S is closed;

Regarding the converter input current, it’s clear that;

In buck converter without input buffer capacitor Ci, as shown in Fig. 4a, during the S-OFF mode, no input current exists thus the input current is discontinuous without Ci.

In the buck converter with input buffer capacitor Ci, as shown in Fig. 4b, during S-OFF period, the presence of buffer capacitor forced the converter input current \({i}_{i}\) to be equal to that capacitor current \({i}_{C}\) in this mode, thus overcoming its discontinuity. However, this capacitor should be relatively large to change the converter input current from discontinuous to continuous which adds to system cost and losses and affects its reliability.

Noticeably, P&O MPPT techniques are widely used in WES, especially for low-cost small-sized standalone ones, for its simplicity and flexibility, in addition to the unnecessity of distributed mechanical speed sensors or anemometers26,26,28, 34. Its tracking strategy depends on perturbing the generator output rectified voltage or current then observes the change in the extracted power to determine direction of control variable perturbation. Accordingly, the MPPT converter duty cycle will be continuously perturbed with a predetermined step size, thus regulating the DC voltage or current to maintain operation around the MPP (zero slope of the power–speed curve)5. Flowchart of the conventional P&O MPPT algorithm is shown in Fig. 5. However, it is worth noting that this method suffers from large power oscillations around the MPP for large step sizes and sluggish response for small ones35. This problem can be limited using variable step sizes which will be explained later.

Flowchart of P&O MPPT algorithm.

As previously discussed, the conventional buck converter topology suffers from input current discontinuity which results in high oscillations in the extracted power, inefficient MPPT and high torque ripples which may affect generator operation. To buffer these oscillations, a large capacitor (Ci) is placed at the buck converter input, yet it affects the entire system life time and reliability as well as increasing its size and cost. To overcome all these limitations, the continuous input/output power DC/DC buck converters introduced in21 are studied and their average models are derived, in the continuous inductor current mode, to select the one with minimal input current ripples to be adopted in this study. Voltage and current gains are derived for each converter along with dynamic analysis of each converter to deduce its input and output current ripples as follows;

Modeling of D4 converter, in the continuous inductor current mode, is originated using Fig. 6a. Voltage and current gains are computed then dynamic analysis is carried out to deduce capacitor voltage ripples \(\Delta {{\varvec{v}}}_{{\varvec{C}}}\) , inductors’ ripple currents \(\Delta {i}_{Li}, \Delta {i}_{Lo}\) and input and output current ripples \(\Delta {i}_{i}, \Delta {i}_{o}\) as shown below;

Circuit topology and switching modes for (a) D4, (b) C1, (c) D6 buck DC/DC converters.

To find voltage and current gains;

The average capacitor current Ic = 0,

Average input power Pi = Average output power Po,

To find the capacitor voltage ripples and inductors’ ripple currents;

When the switch S is closed;

Since, average of inductor voltages = 0

To find input and output ripple currents;

Modeling of C1 converter, in the continuous inductor current mode, is originated using Fig. 6b. Voltage and current gains are computed then dynamic analysis is carried out to deduce capacitor voltage ripples \(\Delta {{\varvec{v}}}_{{\varvec{C}}}\) , inductors’ ripple currents \(\Delta {i}_{Li}, \Delta {i}_{Lo}\) and input and output current ripples \(\Delta {i}_{i}, \Delta {i}_{o}\) as shown below;

To find voltage and current transfer gains;

The average capacitor current Ic =0,

Average input power Pi = Average output power Po,

To find the capacitor voltage ripples and inductors’ ripple currents;

When the switch S is closed;

Since, average of inductor voltages = 0

To find input and output ripple currents;

Modeling of D6 converter, in the continuous inductor current mode, is originated using Fig. 6c. Voltage and current gains are computed then dynamic analysis is carried out to deduce capacitor voltage ripples \(\Delta {{\varvec{v}}}_{{\varvec{C}}}\) , inductors’ ripple currents \(\Delta {i}_{Li}, \Delta {i}_{Lo}\) and input and output current ripples \(\Delta {i}_{i}, \Delta {i}_{o}\) as shown below;

To find voltage and current transfer functions;

The average capacitor current Ic = 0,

Average input power Pi = Average output power Po,

To find the capacitor voltage ripples and inductors’ ripple currents;

When the switch S is closed;

Since, average of inductor voltages = 0

To find input and output ripple currents;

Table 2 summarizes the considered buck converters' performance parameters. It’s vivid that the D4, C1 and D6 converters feature continuous input current unlike the conventional buck converter, thus eliminating the required buffer capacitor at converter input which in turn increases system lifetime and reduces its size and cost. However, these three converters differ regarding the input current ripples which are mirrored in the extracted power oscillations thus affecting the extracted power value and the converter tracking performance. Referring to Table 2, D6 converter experiences the least input current ripples i.e. the least tracked power oscillations. Thus, it will be selected to be applied in the considered WECS, instead of the conventional buck converter, to eliminate the need of buffer capacitor and meanwhile minimize power oscillations and maximize the tracked power.

Comparing buck converter with input buffer capacitor to D6 converter, the latter shows superior performance. This can be concluded from converters’ modes of operation shown in Figs. 4b and 6c respectively and derived ripples’ equations presented in Table 2.

Regarding capacitor voltage ripples, in both cases, it depends on converter input current as deduced from Table 2. However, although a relatively large buffer capacitor is placed at buck converter input to overcome its discontinuity, still high ripples in input current exist resulting in large input voltage ripples and in turn large capacitor voltage ripples since the buffer capacitor is placed directly in parallel to converter input. Oppositely, in D6, the capacitor is separated from converter input by an input inductor which filters input current resulting in minimal capacitor voltage ripples. Hence a comparatively quite smaller linkage capacitor is required in D6 than that required at the buck converter input.

Regarding inductor current ripples, it’s clear from Table 2 that D6 input inductor current ripples, \(\Delta {i}_{Li}= \frac{{\Delta v}_{C}D}{{f}_{sw}{L}_{i}}\) , which is meanwhile the converter input current, just depends on the small capacitor voltage ripples, unlike the buck inductor current ripples which depend on converter input rippled voltage, \({\Delta i}_{L}=\frac{{V}_{i}D(1-D)}{{f}_{sw}L}\) . Moreover, an additional output inductor exists in D6 to aid the input one resulting in low sizes for input and output inductor of D6, compared to that of buck inductor.

As previously discussed, D6 CICO power converter is applied in the considered WECS as it features minimal input current ripples. Thus, maximum tracking efficiency can be achieved without the need of buffer capacitor which reduces system size and cost and enhances system reliability. To add to these merits, D6 converter acting as the MPP tracker will use a variable-step P&O scheme to solve the tradeoff between tracking speed and accuracy. Finally, another modification is proposed to D6 control in order to eliminate the need for a current sensor by estimating the DC rectified current from D6 derived averaged state space model rather than directly measuring it. Hence, current sensorless MPPT is achieved to add to system cost effectiveness and compact size.

The State Space Averaging method is widely used by the power electronics industry giving quite insight into the converter behavior36. The dynamic small signal model of D6 is derived based on its averaged state-space model which is divided into two sub-models, each addressing certain converter dynamics. The first sub-model analyzes the converter behavior when the converter switch (S) is at the ON state (i.e. switching period from 0: DT) while the second sub-model offers converter dynamics when the switch (S) is at OFF (i.e. switching period from DT: T). For each region, the corresponding state-space sub-model is deduced and finally the total state-space model, averaged along the total switching period, is derived. Inductors and capacitor’s internal resistances are neglected for sake of simplicity.

State-space sub-model when Switch “S” is ON

From Fig. 6c, during switching ON period (t = 0-DT), the following state-space equations can be derived;

where \({V}_{DC-bus}\) is the DC bus voltage at D6 converter output (\({V}_{DC-bus}={V}_{o}\) ) and it is constant = 400 V while \({V}_{r}\) is the generator rectified voltage which is input to D6 converter (\({V}_{r}={V}_{i}\) ) and has to be regulated by the MPPT controller to force operation around the MPP. Both \({V}_{DC-bus}\) and \({V}_{r}\) are considered model inputs. y is the model output which is the generator rectified current \({I}_{r}\) which is meanwhile D6 input current Ii. This current is to be estimated by the sensorless MPPT controller rather than being sensed thus eliminating its sensor.

Equations (38–41) are rearranged to obtain the linear time-invariant state-space sub-model given by;

State-space sub-model when Switch “S” is OFF

From Fig. 6c, during switching OFF period (t = DT-T), the following state-space equations can be derived;

Equations (43–46) are rearranged to obtain the linear time-invariant state-space sub-model given by;

For a clear insight of entire system dynamics, the total system averaged state-space model is found to be;

and d is the instantaneous value of D6 converter duty ratio.

Hence, applying the latter to system state space sub-models, presented in (42) and (47), the total averaged state-space model of the proposed system is given by (49);

Based on the derived averaged state-space model of the selected D6 converter, the state space block diagram, shown in Fig. 7, is obtained. This diagram is the base upon which the proposed sensorless MPPT scheme is realized since the output of this model is the rectified input current of D6 converter which will be estimated using this model rather than being directly sensed using a current sensor. Conclusively, the derived averaged state-space model of D6 is used to estimate the converter input current which will be injected into the sensorless MPPT process to track the maximum power of the considered WECS. This will save the cost of the eliminated current sensor which enhances system cost-effectiveness.

Block diagram of the derived averaged state-space model of D6 converter.

A current sensorless MPPT scheme is proposed which consists of two main stages. In the first stage, the rectified DC current is estimated from D6 averaged state-space model derived in the previous subsection, rather than directly measuring it through a DC current sensor. Then in the second stage, the estimated rectified current along with the measured rectified voltage are utilized by a variable step P&O MPPT algorithm to extract the maximum available power and force converter operation around the MPP. The two stages are discussed in details as follows.

The first stage is responsible for observing and estimating the rectified generator current which is the converter input current from D6 averaged state-space-based dynamic model which is derived in the previous section. However, to achieve this, the derived model should be checked for its observability i.e. to ensure system capability of using model input and output to estimate the converter rectified current from the derived model to be injected later in the MPPT process. For the system to be completely state observable, the observability matrix Qo of dimension n*n has to be full column rank i.e. its rank = n37. This means that the matrix has n independent pivot columns which occurs when it has a non-zero determinate i.e. \(\left|{{\varvec{Q}}}_{{\varvec{o}}}\right|\ne 0\) as shown below37;

So, to check the observability of D6 derived model, first the observability matrix Qo is computed as follows;

Hence, for an observable model from which the converter input current can be estimated \(\left|{{\varvec{Q}}}_{{\varvec{o}}}\right|\ne 0 \to -\frac{d}{{L}_{i}^{2}C}\ne 0\) i.e. the duty ratio d \(\ne 0\) . Thus, the converter input current can be estimated rather than being directly sensed, eliminating the current senor.

To realize the current online estimation, the small signal model, shown in (49), is represented by the block diagram shown in Fig. 7. This block diagram presents the model in a block form rather than in matrix form thus simplifying the sensorless scheme realization. As concluded from the block diagram, the model output Ir, which is the estimated rectified current input to D6, is estimated by measuring solely the rectified voltage Vr given that DC-bus voltage is constant. Thus, the current sensor can be eliminated and this control block can be implemented on a simple controller to substitute for the current sensor absence. The predicted current signal along with the measured voltage signal are fed to the controller second stage which is responsible for MPPT as described later.

Figure 8 shows the conventional sensored MPPT controller versus the proposed sensorless variable step one. Unlike the conventional single-stage MPP controller which requires both voltage and current sensors, the proposed sensorless controller requires only one voltage sensor and includes two sequential stages; current estimation stage followed by MPPT stage. Thus, the proposed current sensorless MPPT scheme has the capabilities of eliminating the current senor thus reducing the MPP controller cost and size as well as achieving noise immunity.

MPPT control using (a) Sensored MPPT controller, (b) Proposed sensorless MPPT controller.

The second following stage employs variable-step P&O-based MPPT algorithm to maintain the operation around the MPP. As previously discussed in the P&O scheme, the rectifier output power versus the rectified voltage is amended to operate at the zero slope for the P–V curve. However, for fixed step sizes38,39, larger step sizes result in oscillation near the MPP affecting tracking accuracy while smaller step sizes increase the tracking time and slow down the response. Thus, to solve the tradeoff between tracking accuracy and convergence speed, much research was introduced to apply steps with varying sizes according to region of operation7. Some use variable step sizes40,40,41,43, others use adaptive44,45 or hybrid ones46.

The variable step size shown in Eq. (51) is a well-known solution to the conflict between tracking accuracy and convergence speed in PV/wind systems where both have a P–V curve that has an optimal MPP at certain environmental condition7,22. Meanwhile, it features easier realization than adaptive and hybrid step sizes which require more tuning and design7. This variable step depends on the slope of the tracked P–V curve (i.e. tracked power change divided by the tracked voltage change) which is big away from the MPP then gets smaller towards that optimal point (at which the slope of the curve = 0)22. Thus, larger-speed step sizes are applied in regions away from the MPP while small step sizes are utilized near the MPP as shown in Fig. 9. This eliminates the drawbacks of fixed step sizes (slow tracking for small fixed step sizes and large power oscillations around the MPP for large fixed step sizes) and enhances the WECS MPPT performance, maximizing the captured power, improving the settling time and reducing the oscillation level. Thus, for direct converter control, the conventionally adopted variable step-size \(\Delta D\) is shown in (51);

and N1 is the scaling factor designed only once at the start of operation.

Variable-step size versus fixed step sizes for MPPT in WES.

The same concept is employed but depending on the slope of the tracked P-I curve in WES (dP/dI)40 while in42 it depends on the slope of mechanical power of the WT versus speed (dP/dω).

However, the conventional variable step-size, being dependent on the division of PV power change by PV voltage change (∆P/∆V), can affect the MPPT performance due to this step size digression, particularly under sudden power changes due to the division issue36. Thus, in this paper, the variable step size is modified to depend solely on \(\left|\Delta {\text{P}}\right|\) rather than \(\left|\frac{\Delta {\text{P}}}{\Delta V}\right|\) as shown in (52);

This will eliminate division computations burden and also enhance the tracking performance as illustrated in Fig. 10. For a change occurring in wind speed, the operating point shifts from ‘X’ to ‘Y’. Thus, a change in rectified current (∆I) occurs reducing the tracked power while almost no ∆V takes place. For a successful transfer to the new MPP ‘M’, the considered MPPT algorithm must decrement the duty ratio D by a convenient step size.

For the widely used ∆P/∆V step, an almost zero ∆V occurs which in turn causes a vast increase in the adopted step-size. Hence, the duty ratio D noticeably decrements shifting operation to ‘Z’ which consequently results in longer tracking time till reaching ‘M’ and a considerable transient power loss.

For the proposed ∆P step, division by ∆V is avoided, thus overcoming the large increase in the step-size. Thus, the operating point is shifted to ‘N’ which is close to the MPP ‘M’, reducing transient power loss and speeding up the tracking process.

Performance of the considered MPPT algorithm when applying (a) ∆P/∆V step and (b) ∆P step.

Conclusively, the employed variable step-size minimizes tracked power ripples, enhances MPPT dynamics and simplifies control complexity due to the eliminated division computation.

Thus, the proposed sensorless MPPT controller, adopting variable-step P&O algorithm, can give satisfactory performance yet with minimum complexity for easier implementation on low-cost microcontrollers. The adopted variable step-size, given by Eq. (52), besides solving the trade-off issue, it depends solely on tracked power change ∆P rather than the ratio ∆P/∆V, thus eliminating division computations and high-power fluctuations around the MPP. Adding to all of this, elimination of current sensor adds to system compactness and cost-effectiveness.

Figure 11 shows system simulation results using the basic buck converter while Fig. 12 demonstrates those of D6 converter. Simulation results include generator torque and mechanical power, converter input current, converter average input tracked power and converter average output power. Table 3 summarizes simulation results’ parameters that include the attained torque ripples \(\Delta {\varvec{T}}\) , mechanical power ripples \(\Delta {P}_{mech}\) , converter input current ripples \(\Delta {I}_{i}\) , converter average input power and its ripples \({P}_{i},\Delta {P}_{i}\) and converter average output power and its ripples \({P}_{o},\Delta {P}_{o}\) for each of the two converters. The converter average input power \({P}_{i}\) shows the power that was successfully tracked by the converter and available at its input where its value is enhanced by the converter ability to minimize the input current ripples. Finally, the converter efficiency which is affected by the converter switching and copper losses is computed by (53). The less the inductor size, the less their copper losses, thus the more available power at the converter output \({P}_{o}\) .

Simulation results of basic = buck converter featuring sensored MPPT; (a) Torque, (b) Mechanical power, (c) Converter input current current, (d) Converter average input power, (e) Converter average output power.

Simulation results of D6 converter featuring sensored MPPT; (a) Torque, (b) Mechanical power, (c) Converter input current, (d) Converter average input power, (e) Converter average output power.

Analyzing Figs. 11 and 12 parts along with Table 3 parameters, both converters were able to adequately track the MPP, during different wind speeds, which validates the applied sensored variable-step P&O scheme. However, there were differences in performance between both converters as explained below.

Despite its larger size passive elements, still noticeably large fluctuations in the buck converter input current exist as shown in Fig. 11c compared to those of D6 input current given by Fig. 12c. These ripples are reflected in the relatively large fluctuations in the generator torque and mechanical power of the basic buck converter (Fig. 11a and b respectively) when compared to those of D6 (Fig. 12a and b respectively), as presented in Table 3, which in turn affects turbine safety. On the other hand, the less fluctuations in D6 converter reduces stresses on the machine and maintains its lifetime.

Moreover, the larger input current ripples in basic buck converter are also mirrored in considerably more power ripples at the converter input thus reducing the available tracked input power (Fig. 11d) when compared to the available input power of D6 with its minimal oscillations (Fig. 12d). This enhanced the tracking performance of D6 during different wind speeds.

Finally, the relatively less size passive elements included in D6 feature less losses i.e. more power available at the converter output during different wind speeds (Fig. 12e when compared to that of basic buck (Fig. 11e). Thus, as shown in Table 3, D6 exceled in the conversion efficiency achieved, experiencing ≥ 99% at different wind speeds. Moreover, remarkable increase in D6 output power can be noticed when compared to that of the traditional buck converter i.e. D6 output power exceeds that of basic buck converter by almost 550, 340, and 60 W at wind speed of 12, 11 and 10 m/s respectively.

These enhancements are related to D6 converter outstanding property of continuous input current which is further reflected on minimal ripples in the converter input power and more available power to be tracked in addition to eliminating the need of the buffer large capacitor. Thus, the whole system reliability, efficiency and tracking time are enhanced along with reducing stresses on machine.

Another experiment is carried out to verify the effectiveness of the proposed sensorless variable-step P&O MPPT scheme. In this experiment, the superior D6 converter is again tested using MATLAB/Simulink under the two considered step changes of wind speed but when applying the proposed sensorless MPPT scheme based on its derived state space averaged model of D6 converter.

Figure 13a–e shows D6 simulation results, when applying the proposed sensorless MPPT scheme, regarding generator torque and mechanical power, converter input current, converter average input tracked power and converter average output power respectively while the third column of Table 3 summarizes D6 performance parameters for these simulation results.

Simulation results of D6 converter featuring sensorless MPPT; (a) Torque, (b) Mechanical power, (c) Converter input current, (d) Converter average input power, (e) Converter average output power.

It can be concluded that using the proposed sensolress MPPT scheme, D6 successfully tracked the MPP during different wind speeds which validates the proposed scheme principle. However, longer tracking time and more ripples are noticed with D6 when using the sensorless controller rather than the sensored one. This can be related to the computations burden and time required to estimate the converter input current value by the sensorless scheme. Despite the small differences between both controllers’ response, the overall performance of both is quite close verifying the proposed sensorless one effectiveness due to its less cost and size. Moreover, D6 converter applying the sensorless scheme still outweighs the basic converter regarding the tracking time, the ripples attained in the applied torque, mechanical power and input current as well as the input and output converter powers’ values. It was able to achieve conversion efficiencies of more than 99% during different wind speeds.

In summary, simulation results demonstrated how the selected CICO D6 converter outweighs the conventional buck one regarding current continuity, minimal electrical and mechanical power ripples and enhanced system reliability and efficiency yet at considerably less capacitor and inductor values. Moreover, the effectiveness of proposed sensorless controller is verified in tracking the MPP during different wind speeds with quite acceptable performance parameters adding to system compactness and cost effectiveness due to the eliminated current sensor.

Generally, small sized decentralized wind energy-based power generation systems require efficient and reliable MPP tracker realized with simple implementation and low-cost microcontrollers. Thus, in this paper, the considered standalone PMSG-based WECS adopts a continuous input current buck converter featuring minimal input current ripples without the need input buffer capacitor, thus system reliability and tracking efficiency are enhanced. Moreover, a current sensorless MPPT controller, based on variable step P&O algorithm, is proposed to add to system simplicity and reduced cost as well as compromise between the tracking time and accuracy. The proposed system capabilities can be summarized as follows;

According to Table 4, the values of passive elements selected in simulation work for the buck converter and D6 are listed. It’s clear that the input capacitor and output inductor of the conventional buck converter outsize those of D6 converter (the converter capacitor and input and output inductors). Despite these relatively larger values, more input current and power ripples have resulted in case of the basic buck converter as verified by simulation results. However, if larger values for buck converter elements are to be selected, system cost and size will greatly increase and the system will be cost-ineffective. Thus, values shown in Table 4 are adopted.

Although there may be some variations in selected elements’ sizes in real-time implementation, yet still buck converter will possess elements of larger size than those of D6. So, the objective of this comparison is to show the effect of element size on element cost and losses and that although D6 is a three-passive element converter, it is less in cost and losses than the two-element buck since it acquires less elements size. For fair comparison, same operating conditions are considered as well as same components’ manufacturer in both converters w.r.t to each element type (capacitor or inductor).

Regarding the cost issue, it varies according to different aspects, mainly component size and operating voltage/current level. According to values presented it Table 4, the cost of each converter passive component is decided based on the prices shown on the website of the trust-worthy electric components’ store; “Mouser electronic components”, Available at: https://eu.mouser.com/.

Regarding D6 converter with same operating conditions only 10 µF is required as per Table 4. Thus, a film capacitor of close specifications (220 µF, 630 V) is chosen for its reliability and relatively much less cost of 4,15€ which is half the cost of buck electrolytic converter and twenty times less than buck film capacitor cost as shown in Table 5. This is related to the smaller size of D6 capacitor compared to that of buck.

The conventional buck output inductor should withstand operating current of almost 40 A which is the converter output current (P/Vo = 15500 W/400 = 39 A). Thus, according to Table 4 values, a 10 mH, 40 A inductor is required for buck converter whereas for D6, a 1 mH, 40 A output inductor and 1 mH, 25 A input inductor are required. However, according to components availability, the following was found at Mouser website;

For buck converter, a 50 A, 10 mH, 0.023 Ω power inductor is available for 760€ whereas for D6 input inductor, a 30 A, 1 mH, 0.009 Ω is available for 96€ and a 50 A, 1 mH, 0.005 Ω for 163.6€ is available for D6 output inductor as shown in Table 6. Hence, it’s clear that the cost of D6 both inductors’ (260€) is still almost three times less than the cost of the single buck inductor due to its larger size. Moreover, the 10mH buck inductor features resistance of 0.023 Ω which is almost five times that of D6 output inductor and 3.5 times that of D6 input inductor as concluded from Table 6 which results in more losses in buck converter.

To reduce the inductor cost, a 50 A, 1 mH, 0.0017 Ω common mode choke inductor is available at 11.45€, yet at the size of 1mH and not available in bigger sizes. Hence, it can be used for the input and output inductors of D6 with total cost of 2*11.45€. However, when applied with the buck, it can be used as a series patch of 10 inductor units to realize total of 50 A, 10*1 mH, 10*0.0017 Ω inductor yet at a bigger size and weight as well as five times the cost of that of D6 in addition to more resistive losses.

Conclusively, the larger capacitor and inductor sizes featured by the two-element buck converter cost way more than those of the three-element D6 due to the latter relatively much smaller sizes.

As per resistive power losses associated with converters’ capacitors, almost close ESR resistances are experienced in the film capacitor associated with buck or D6, yet the high voltage ripples buffered by buck capacitor can increase its losses. However, for cost-effectiveness, if an electrolytic capacitor is used with buck, it features a quite bigger ESR resistance as shown in Table 5 i.e. more losses. Normally, electrolytic capacitors have larger internal power loss for same amount of ripple current compared to film ones47.

Regarding resistive power losses experienced by converters’ power inductors, the input and output power inductors of D6 exert relatively less resistances values (RLi = 0.009 Ω, RLo = 0.005 Ω) compared to that of buck output inductor (RL = 0.023 Ω), as shown in Table 6, resulting in total average power losses for both D6 inductors altogether less than that exerted by the buck single inductor.

For Ii = 25 A and Io = 40 A,

As per losses experienced by converters’’ choke inductors, the average losses exerted by buck converter inductor units are quite larger than those of D6 input and output inductors altogether since buck is made of 10 series inductor units as shown in Table 6 while each inductor in D6 is a single unit (as in simulation case).

For Ii = 25 A and Io = 40 A,

\(For\;D6;P_{loss - D6} = I_{i}^{2} \left( {0.0017} \right) + I_{o}^{2} \left( {0.0017} \right) = 3.78\;{\text{W}}\;whereas\;for\;buck\;P_{loss - buck} = 10I_{o}^{2} \left( {0.0017} \right) = 27.2\;{\text{W}}\)

Conclusively, although buck has two passive elements rather than the three-element D6, it acquires more resistive power losses due to its components’ relatively larger size.

As previously explained in the cost aspect, for cost effectiveness, the buck film capacitor can be replaced by electrolytic capacitor. However, electrolytic capacitors experience less lifetime affecting reliability in case of high current ripples which is the case of the buck converter47. The application of excessive mechanical stress or excessive electrical parameters such as operating voltage and ripple currents cause poor contact or open circuits in electrolytic capacitors causing its degradation & shortens its life span48.

Although the buck converter features larger passive elements than those of D6, still it experiences larger input current ripples as shown in Fig. 11c compared to that of D6, Fig. 12c due to buck converter inherited feature of pulsating input current. This results in larger ripples in the power tracked by buck converter, more losses and less captured power which affects system efficiency as concluded from simulation results summarized in Table 3. Moreover, these fluctuations are mirrored in relatively larger mechanical power and torque fluctuations which affect turbine safety.

In summary, despite having less component-count, the conventional buck experiences more cost, losses and less reliability than D6 due to the former relatively larger components’ sizes. Moreover, despite larger passive elements employed by the traditional buck converter, it still experiences larger power oscillations and torque fluctuations. Thus, D6 has merits of reduced cost, size and losses, enhanced reliability, efficiency and tracking performance as well as less stress on machine which are appealing features for off-grid self-sufficient RES applications where power supply is totally independent of utility.

Proposed current sensorless P&O-based MPPT scheme

P&O MPPT algorithm is very popular in small-size, low-cost systems since, in such systems, it gives successful tracking performance with the merits of simple implementation and control, thus can implemented using low-cost microcontrollers. Moreover, no mechanical sensors or prior knowledge of WT parameters are required since it depends solely on measuring the rectified voltage and current to achieve accurate MPPT. Thus, in this study, P&O is adopted. However, an added merit is proposed to the applied scheme where the current sensor is also removed and the converter input current is estimated using the state-space model of the selected D6 converter, Thus, further reduction to system size and cost is realized without affecting the MPPT process as verified by simulation results.

Perturbing the control variable in the MPPT process, which is the converter duty ratio, using the proposed variable step size solves the trade-off between extracted power oscillations and the tracking convergence speed. Moreover, eliminating the division in the step size reduces the computational burden thus decreasing software complexity. A number of studies applied P&O based MPPT schemes in WECS38,38,39,40,41,42,43,44,46. Fixed step-sizes38,39 result in either high power oscillations around the MPP for fast tracking or low convergence speed for less ripples. Thus, selecting the step-size is challenging and tracking performance is greatly affected. To solve this issue, the fixed step-size is replaced by variable40,40,41,43, adaptive44,45 or hybrid ones46.

Adaptive step sizes are defined for each perturbation depending on a definite objective function which clarifies the relation among control variables and wind speed. This function can be dependent on multiple constants which need to be accurately tuned, thus increasing control complexity. Hybrid step sizes result from the combination of step-sizes of different types while MPP tracking is employed. However, their operation order and activation need accurate design which again adds to control complexity. Although adaptive and hybrid step sizes achieve very good compromise between oscillations and speed, their tuning and design requirements add to implementation complexity and require user experiene7. Featuring less complexity, variable step-sizes, are simpler in realization than the latter and their tuning requirements are minimal7. Meanwhile low oscillations around the MPP and high tracking speed are well addressed. Hence, in the proposed MPPT scheme, variable step-size is selected since it combines between less complexity, minimal design requirements and successfully solves the tradeoff issue.

Table 7 compares different P&O schemes applied to WECS, presented in literature, with the proposed one. The proposed current sensorless MPPT scheme, based on division-free variable step-size P&O algorithm, combines between simple implementation, efficient tracking performance and a good compromise between tracking speed and power oscillations yet at the minimal design requirements and component count. Notably, due to the eliminated current sensor, it outweighs the others regarding size and cost. However, it is worth noting that the proposed sensorless scheme is converter dependent since it depends on the applied converter state space model i.e. changing the converter topology implies to derive the new converter state space model to help estimate the rectified current rather than measuring it.

For decentralized WECS, the implemented converter topology, its input power continuity and the employed MPPT algorithm have a significant impact on system electric power tracking performance, conversion efficiency as well as its produced mechanical power and torque nature. Thus, in this paper, three continuous input/continuous output power buck converters (D4, C1 and D6) are studied and their dynamic models are derived to select the one with the least input current ripples. D6 converter was selected since it shows minimal input power ripples and in turn best tracking performance. Moreover, a current sensorless MPPT algorithm is proposed to be applied on the selected converter topology. Being dependent on division-free variable-step P&O algorithm, the proposed MPPT scheme features the merits of simple realization, absence of any mechanical sensors and enhanced compromise between tracking time and accuracy as well as reduced size and cost due to the eliminated current sensor. Simulation results verify the superiority of the selected D6 converter when compared with the traditional buck achieving minimal mechanical and electrical power oscillations with less inductor and capacitor sizes, all of which enhance tracking time and system reliability as well as increasing the available tracked power and decreases system total cost and losses. Finally, the functionality of the proposed current sensorless MPPT controller is also verified using simulation results during varying wind speeds which adds to system cost effectiveness and compactness.

Aliyu, A. K., Modu, B. & Tan, C. W. A review of renewable energy development in Africa: A focus in South Africa, Egypt and Nigeria. Renew. Sustain. Energy Rev. 81, 2502–2518 (2018).

Hossain, M. M. & Ali, M. H. Future research directions for the wind turbine generator system. Renew. Sustain. Energy Rev. 49, 481–489 (2015).

Njiri, J. G. & Söffker, D. State-of-the-art in wind turbine control: Trends and challenges. Renew. Sustain. Energy Rev. 60, 377–393 (2016).

Albassioni, B. T. et al. Wind energy conversion system topologies and converters: Comparative review. Energy Procedia 162, 38–47 (2019).

Sachan, A., Gupta, A. K. & Samuel, P. A Review of MPPT algorithms employed in wind energy conversion systems. J. Green Eng. 6(4), 385–402 (2017).

Kumar, M. B., Saravanan, B., Sanjeevikumar, P. & Blaabjerg, F. Review on control techniques and methodologies for maximum power extraction from wind energy systems. IET Renew. Power Gener. 12(14), 1609–1622 (2018).

Pande, J., Nasikkar, P., Kotecha, K. & Varadarajan, V. A Review of maximum power point tracking algorithms for wind energy conversion systems. J. Mar. Sci. Eng. 9(1187), 1–30 (2021).

Elbeji, O., Hannachi, M., Benhamed, M. & Sbita, L. Maximum power point tracking control of wind energy conversion system driving a permanent magnet synchronous generator: Comparative study. Wind Eng. 45(5), 1072–1081 (2021).

Koondhar, M. A. et al. Wind energy conversion system using maximum power point tracking technique - A comprehensive survey. Appl. Eng. Lett. 6(4), 148–156 (2021).

Naoui, M. et al. Comparative analysis of MPPT techniques for enhancing a wind energy conversion system. Front. Energy Res. 1–15 (2022).

Zhang, X. et al. Maximum power point tracking algorithms for wind power generation system: Review, comparison and analysis. Energy Sci. Eng. 1–15 (2022).

Dursun, E. H. & Kulaksiz, A. A. MPPT control of PMSG based small-scale wind energy conversion system connected to DC-bus. Int. J. Emerg. Electr. Power Syst. 21(2), 20190188 (2020).

Chaicharoenaudomrung, K. et al. Maximum power point tracking for stand-alone wind energy conversion system using FLC-P&O method. IEEJ Trans. Electr. Electron. Eng. 15, 1723–1733 (2020).

Cheng, M. & Zhu, Y. The state of the art of wind energy conversion systems and technologies: A review. Energy Convers. Manag. 88, 332–347 (2014).

Vijayaprabhu, A., Bhaskar, K. B., Jasmine Susila, D. & Dinesh, M. Review and comparison of various types of generation using WECS topologies. In IOP Conference Series: Materials Science and Engineering, 2021 Vol. 1177 012004 (2021).

Carroll, J., McDonald, A. & McMillan, D. Reliability comparison of wind turbines with DFIG and PMG drive trains. IEEE Trans. Energy Convers. 30, 663–670 (2015).

Nejad, A. R. et al. Wind turbine drivetrains: State-of-the-art technologies and future development trends. Wind Energy Sci. Discuss. 7, 387–411 (2022).

Cornea, O., Hulea, D., Muntean, N. & Andreescu, G. D. Step-down switched-inductor hybrid DC-DC converter for small power wind energy conversion systems with hybrid storage. IEEE Access 8, 136092–136107 (2022).

Bauomy, M. F., Gamal, H. & Shaltout, A. A. Wind energy DC nanogrid dynamic modelling and MPPT operation. In Proceeding of the International Conference on Smart Grid and Renewable Energy (SGRE), 2019 1–7 (2019).

Huangfu, Y., Ma, R., Liang, B. & Li, Y. High power efficiency buck converter design for standalone wind generation system. Int. J. Antennas Propag. 1–9 (2015).

Williams, B. W. DC-to-DC converters with continuous input and output power. IEEE Trans. Power Electron. 28(5), 2307–2316 (2013).

Zakzouk, N. E. & Ibrahim, R. A. Modelling and performance analysis of a buck converter featuring continuous input/ continuous output current for wind energy-DC microgrid. In Proceeding of the 6th International Conference on Green Energy and Applications (ICGEA), 2022 127–132 (2022).

Chen, J. & Chen, J. On reducing the shaft torque ripple of small-to-medium-scale wind energy conversion systems using multi-pulse autotransformer rectifier. Energies 11(2), 379–396 (2018).

Khateb, A. H. E., Rahim, N. A., Selvaraj, J. & Williams, B. W. DC-to-DC converter with low input current ripple for maximum photovoltaic power extraction. IEEE Trans. Ind. Electron. 62(4), 2246–2256 (2015).

Zakzouk, N. E., Khamis, A. K., Abdelsalam, A. K. & Williams, B. W. Continuous-input continuous-output current buck-boost DC/DC converters for renewable energy applications: Modelling and performance assessment. Energies 12(11), 2208. https://doi.org/10.3390/en12112208 (2019)

Pandya, B., Joshi, S. & Mehta, N. Comparative analysis of MPPT algorithms for small scale wind energy system. In Proceeding of the International Conference on Sustainable Energy and Future Electric Transportation (SEFET), 2021 1–6 (2021).

Mousa, H. H. H., Youssef, A. R. & Mohamed, E. E. M. State of the art perturb and observe MPPT algorithms-based wind energy conversion systems: A technology review. Int. J. Electr. Power Energy Syst. 126, 106598 (2021).

Aourir, J. & Locment, F. Limited power point tracking for a small-scale wind turbine intended to be integrated in a DC Microgrid. Appl. Sci. 10(22), 8030 (2020).

Bansal, D. & Pandey, K. Blade pitch angle and tip speed ratio control schemes for constant power generation of WECS. In Proceedings of the IEEE International Conference on Power Electronics, Intelligent Control and Energy Systems (ICPEICES), 2016 1–6 (2016).

González‐Hernández, J. G. & Salas‐Cabrera, R. Maximum power coefficient analysis in wind energy conversion systems: questioning, findings, and new perspective. Math. Probl. Eng. (2021).

Saad, N. H., El-Sattar, A. A. & Marei, M. E. Improved bacterial foraging optimization for grid connected wind energy conversion system based PMSG with matrix converter. Ain Shams Eng. J. 9(4), 1–11 (2017).

Erickson, R. W. & Maksimovic, D. Fundamentals of Power Electronics (Springer, 2020).

Switching Regulator IC series: Capacitor Calculation for Buck converter IC, ROHM semiconductor -application note. https://fscdn.rohm.com/en/products/databook/applinote/ic/power/switching_regulator/capacitor_calculation_appli-e.pdf.

Dalala, Z. M. et al. Design and analysis of an MPPT technique for small-scale wind energy conversion systems. IEEE Trans. Energy Convers. 28(3), 756–767 (2013).

Kazmi, S. M. R., Goto, H., Hai-Jiao, G. & Ichinokura, O. A novel algorithm for fast and efficient speed-sensorless maximum power point tracking in wind energy conversion systems. IEEE Trans. Ind. Electron. 58, 29–36 (2011).

Khamis, A. K., Zakzouk, N. E. & Abdelsalam, A. K. Generalized cost-effective converter for solar street lighting featuring averaged state-space model-based sensorless MPPT. Comput. Electr. Eng. 101, 1–19 (2022).

Nozari, E. Linear Systems and Control: Stability, Controllability & Observability, University of California, Riverside. Available at: https://intra.engr.ucr.edu/~enozari/teaching/ME120_Fall20/Lecture%203%20-%20Stability,%20Controllability%20&%20Observability.pdf (2020).

Linus, R. M. & Damodharan, P. Maximum power point tracking method using a modified perturb and observe algorithm for grid connected wind energy conversion systems. IET Renew. Power Gener. 9, 682–689 (2015).

Billel, M., Abdallah, S., Yassine, A. & Djalel, D. Maximum power extraction (SMC & P&O) from wind energy system based on reliable control. Rev. Sci. Technol. 6, 70–85 (2015).

Fathabadi, H. Novel high efficient speed sensorless controller for maximum power extraction from wind energy conversion systems. Energy Convers. Manag. 123, 392–401 (2016).

Mousa, H. H., Youssef, A. R. & Mohamed, E. E. Variable step size P&O MPPT algorithm for optimal power extraction of multi-phase PMSG based wind generation system. Int. J. Electr. Power Energy Syst. 108, 218–231 (2019).

Mousa, H. H., Youssef, A. R. & Mohamed, E. E. Modified P&O MPPT algorithm for optimal power extraction of five-phase PMSG based wind generation system. SN Appl. Sci. 1, 1–16 (2019).

Meghni, B., Ouada, M. & Saad, S. A novel improved variable-step-size P&O MPPT method and effective supervisory controller to extend optimal energy management in hybrid wind turbine. Electr. Eng. 102, 763–778 (2020).

Mozafarpoor-Khoshrodi, S. H. & Shahgholian, G. Improvement of perturb and observe method for maximum power point tracking in wind energy conversion system using fuzzy controller. Energy Equip. Syst. 4, 111–122 (2016).

Youssef, A. R., Mousa, H. H. & Mohamed, E. E. Development of self-adaptive P&O MPPT algorithm for wind generation systems with concentrated search area. Renew. Energy 154, 875–893 (2020).

Mousa, H. H., Youssef, A. R. & Mohamed, E. E. Hybrid and adaptive sectors P&O MPPT algorithm-based wind generation system. Renew. Energy 145, 1412–1429 (2020).

Power Film Capacitors Versus Aluminum Electrolytic Capacitors for DC Link Applications. Advances in Capacitors and Ultracapacitors for Power Electronics—Industrial Session1.3 (2013).

Morrison, S. Electrolytic Capacitor failure and how it affects circuits, the tech circuit electronics courses and education for appliance and HVAC technicians 2020. Available at: Electrolytic Capacitor Failure and How it Affects Circuits—The Tech Circuit™ (2020).

Open access funding provided by The Science, Technology & Innovation Funding Authority (STDF) in cooperation with The Egyptian Knowledge Bank (EKB).

Electrical and Control Engineering Department, Arab Academy for Science, Technology and Maritime Transport, Abukir, Alexandria, 1029, Egypt

You can also search for this author in PubMed  Google Scholar

The author has achieved (a) conception and design, analysis and interpretation of the data; (b) drafting the article and revising it critically for important intellectual content; and (c) approval of the final version.

Correspondence with Nahla E. Zakzouk.

The author declares no competing interests.

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Zakzouk, N.E. Continuous input current buck DC/DC converter for small-size wind energy systems featuring current sensorless MPPT control. Sci Rep 14, 380 (2024). https://doi.org/10.1038/s41598-023-50692-2

DOI: https://doi.org/10.1038/s41598-023-50692-2

Anyone you share the following link with will be able to read this content:

Sorry, a shareable link is not currently available for this article.

Provided by the Springer Nature SharedIt content-sharing initiative

Scientific Reports (Sci Rep) ISSN 2045-2322 (online)

smelting capacitor Sign up for the Nature Briefing: AI and Robotics newsletter — what matters in AI and robotics research, free to your inbox weekly.